Carrier 58MVB Series Product Data
Carrier 58MVB Series Product Data

Carrier 58MVB Series Product Data

Deluxe 4-way multipoise variable-speed condensing gas furnace

Advertisement

Copyright 2005 Carrier Corporation
Product
Data
Model 58MVB
Deluxe 4-Way Multipoise
Variable-Speed
Condensing Gas Furnace
Input Rates: 40,000 thru 120,000 Btuh
Comfort Heat™ technology,
the ultimate in
heating comfort . . .
The Carrier Infinity™ 96 with Com-
fortHeat™ technology achieves the opti-
mum combination of comfort and
efficency.
The Infinity™ 96 achieves industry-
leading ultra-high efficiency at up to
96.6 percent Annual Fuel Utilization Ef-
ficiency (AFUE). Efficient performance
is enhanced through the variable-speed
design. To maintain ideal comfort, Com-
fortHeat™ technology automatically ad-
justs the heating level, maximizing the
use of low heating levels that produce
near silent furnace operation while meet-
ing the exact heating needs. This unit is
designed to keep the indoor temperature
within 1 degree of the thermostat set-
point. Because it operates in low heat
most of the time, the Infinity™ 96 uses
up to 80% less power than single-capac-
ity furnaces.
In addition to providing ultimate com-
fort, the Infinity™ 96 has a sealed com-
bustion system. This system brings
combustion air to the furnace and vents
flue gases outside the furnace in a safe
manner. Because it is sealed, operational
noise is minimal. A sealed combustion
system also means fewer cold drafts and
less air infiltration.
Quality materials are the key behind the
Infinity™ 96's outstanding perfor-
mance. Carrier stands behind quality.
We offer lifetime warranty protection*
on the heat exchangers, the heart of the
Infinity™ 96. The rest of the unit is
backed by a limited 5-year warranty.
The Infinity™ 96 is available in 6 heat/
airflow combinations. The unit has a
4-way multipoise design and can be
installed in upflow, downflow, or
Infinity™ 96
Series 100
Catalog No. 58MVB-1PD

Advertisement

Table of Contents
loading

Summary of Contents for Carrier 58MVB Series

  • Page 1 Series 100 Input Rates: 40,000 thru 120,000 Btuh Comfort Heat™ technology, the ultimate in heating comfort . . . The Carrier Infinity™ 96 with Com- fortHeat™ technology achieves the opti- mum combination of comfort and efficency. The Infinity™ 96 achieves industry- leading ultra-high efficiency at up to 96.6 percent Annual Fuel Utilization Ef-...
  • Page 2 Certifications — The Infinity™ 96, 16 minutes of low heat before switching 20% off your cooling costs! Model 58MVB units are CSA. (A.G.A. to high heat unless the room thermostat and C.G.A.) design certified for use with ComfortHeat™ — On the coldest days has been satisfied.
  • Page 3 A02287 NOTES: 1. The 58MVB Furnace is built for use with natural gas. The furnace can be converted for propane gas with a factory-authorized and listed accessory conversion kit. 2. Control location and actual controls may be different than shown above.
  • Page 4: Model Number Nomenclature

    060 — 60,000 Btuh 080 — 80,000 Btuh 100 — 100,000 Btuh Media Filter Cabinet included 120 — 120,000 Btuh Carrier accessories * UNIT SIZE 040-14 060-14 080-14 080-20 100-20 120-20 2-in. — KGAVT0101BRA VENT TERMINATION KIT (Bracket Only for 2 Pipes) 3-in.
  • Page 5 Carrier accessories * continued UNIT SIZE 040-14 060-14 080-14 080-20 100-20 120-20 ADVANCED PRODUCT MONITOR (software and hardware to link KGAFP0201APM pc laptop to control board) HK44EA120 ECM CONTROL REPLACEMENT MODULE - 1/2 HP HK52EA120 ECM CONTROL REPLACEMENT MODULE - 1 HP...
  • Page 6 Carrier cased coil is used. It One pipe runs inside the other is A.G.A. design certified for allowing venting through the...
  • Page 7 Cleans the air of smoke, dirt, By adding moisture to winter- Available in programmable Carrier’s energy or heat and many pollens commonly dry air, a Carrier humidifier and non-programmable mod- recovery ventilators exhaust found. Saves decorating and can often improve comfort...
  • Page 8: Physical Data

    Physical data UNIT SIZE 040-14 060-14 080-14 080-20 100-20 120-20 DIRECT-DRIVE MOTOR Hp (ECM) MOTOR FULL LOAD AMPS 12.8 12.8 12.8 Variable 250 — 1300 RPM (Nominal) — SPEEDS 11 x 10 10 x 7 11 x 10 11 x 10 11 x 10 11 x 10 BLOWER WHEEL DIAMETER X WIDTH (In.)
  • Page 9 AIR DELIVERY - CFM (Bottom Return With Filter)* Unit Operating Mode CFM Airflow External Static External Static Pressure (ESP) Size Setting Pressure Range* AIRFLOW (CFM) †† Low Heat 585† 0-0.60 040-14 High Heat 0-1.0 †† 1-1/2-Ton Cooling 0-0.50 ‡ †† 2-Ton A/C Cooling 0-0.90 ‡...
  • Page 10 AIR DELIVERY - POWER DRAW (WATTS)** Unit Operating Mode CFM Airflow External Static External Static Pressure (ESP) Size Setting Pressure Range* POWER DRAW (WATTS)** 040-14 †† Low Heat 585 † 0-0.60 High Heat 0-1.0 †† 1-1/2-Ton Cooling 0-0.50 ‡ †† 2-Ton A/C Cooling 0-0.90 ‡...
  • Page 11: Condensate Trap

    Dimensions COMBUSTION-AIR PIPE FOR NON-DIRECT (1-PIPE) VENT APPLICATION (SIZES 040 THROUGH 120 ONLY) FIELD-SUPPLIED 2-IN. DIAMETER FIELD-SUPPLIED PVC 90 ELBOW 2-IN. DIAMETER LENGTH OF STRAIGHT PVC PIPE PIPE PORTION OF COMBUSTION AIR INLET PIPE ASSEMBLY (IN.) CASING WIDTH 17-1/2 8-1/2 ± 1/2 10-1/2 ±...
  • Page 13 DOWNFLOW SUBBASE DIMENSIONS (In.) FURNACE PLENUM OPENING* FLOOR OPENING HOLE NO. CASING FURNACE IN DOWNFLOW APPLICATION FOR WIDTH WIDTH ADJUSTMENT Furnace with or without Cased Coil 17-1/2 15-1/8 16-3/4 20-3/8 Assembly or Coil Box Furnace with or without Cased Coil 18-5/8 20-1/4 20-3/8...
  • Page 14: Electrical Data

    Electrical data UNIT SIZE 040-14 060-14 080-14 080-20 100-20 120-20 UNIT VOLTS — HERTZ — PHASE 115 — 60 — 1 OPERATING VOLTAGE RANGE (Min — Max) 104 — 127 MAXIMUM UNIT AMPS 13.8 13.8 13.8 MINIMUM WIRE SIZE MAXIMUM WIRE LENGTH (Ft)‡ MAXIMUM FUSE OR CKT BKR (Amps) TRANSFORMER (24v) 40va...
  • Page 15 Combustion-air and vent piping for Direct Vent/2-Pipe (All Sizes) and Non-Direct Vent/1-Pipe (Sizes 040 through 120 Only) Applications Maximum Allowable Pipe Length (Ft) NON-DIRECT VENT DIRECT VENT (2-PIPE) ONLY NUMBER OF 90° ELBOWS (1-PIPE) ONLY UNIT SIZE ALTITUDE Termination Pipe Dia (BTUH) Pipe Dia Type...
  • Page 16 Combustion-air and vent piping for Direct Vent/2-Pipe (All Sizes) and Non-Direct Vent/1-Pipe (Sizes 040 through 120 Only) Applications Maximum Allowable Pipe Length (Ft) Continued NON-DIRECT VENT DIRECT VENT (2-PIPE) ONLY NUMBER OF 90° ELBOWS (1-PIPE) ONLY UNIT SIZE ALTITUDE Termination Pipe Dia (BTUH) Pipe Dia...
  • Page 17 Combustion-air and vent piping for Direct Vent/2-Pipe (All Sizes) and Non-Direct Vent/1-Pipe (Sizes 040 through 120 Only) Applications Maximum Allowable Pipe Length (Ft) Continued NON-DIRECT VENT DIRECT VENT (2-PIPE) ONLY NUMBER OF 90° ELBOWS (1-PIPE) ONLY UNIT SIZE ALTITUDE Termination Pipe Dia (BTUH) Pipe Dia...
  • Page 18 MAXIMUM ALLOWABLE EXPOSED VENT PIPE LENGTH (FT) WITH INSULATION IN WINTER DESIGN TEMPERATURE AMBIENT* INSULATION THICKNESS (IN.)† WINTER DESIGN MAX PIPE DIA UNIT SIZE TEMP °F (IN.) 040-14 - 20 060-14 - 20 080-14 080-20 - 20 2-1/2 100-20 2-1/2 - 20 2-1/2 120-20...
  • Page 19: Clearance To Combustibles

    Clearance to combustibles INSTALLATION This forced air furnace is equipped for use with natural gas at altitudes 0 - 10,000 ft (0 - 3,050m), except 140 size furnaces are only approved for altitudes 0 - 7,000 ft. (0 - 2,135m). An accessory kit, supplied by the manufacturer, shall be used to convert to propane gas use or may be required for some natural gas applications.
  • Page 20: Typical Installations

    Typical installations COMBUSTION AIR PIPE (DIRECT VENT/2-PIPE APPLICATION) OUTDOOR UNIT VENT PIPE A/C COIL HUMIDIFIER COMBUSTION AIR INLET (NON-DIRECT 1-PIPE APPLICATION) GAS-FIRED WATER HEATER ELECTRONIC AIR CLEANER FRONT OF AIRFLOW FURNACE A05064 Basement — Upflow Application A05064 ELECTRONIC AIR CLEANER VENT COMBUSTION AIR INLET (NON-DIRECT...
  • Page 21 COMBUSTION-AIR INLET (NON-DIRECT VENT/1-PIPE APPLICATION) COMBUSTION–AIR PIPE VENT PIPE DIRECT VENT/2-PIPE APPLICATION) ELECTRONIC AIR CLEANER FRONT OF FURNACE FURNACE CONDENSATE DRAIN AIR CONDITIONING COIL REFRIGERATION PIPING AIRFLOW A05066 Attic — Horizontal Application A05066 COMBUSTION– AIR PIPE COMBUSTION - AIR INLET (DIRECT VENT/2-PIPE (NON-DIRECT VENT/ APPLICATION)
  • Page 24 • Copyright 2005 Carrier Corporation Indianapolis, IN 46231 9-05 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book Page 24 Printed in U.S.A. PC 101 Catalog No. 58MVB-1PD...

Table of Contents