Cisco Ucs C250 Server Cabling; Lsi Sas3081E-R Pcie Card; Lsi Megaraid Sas 9261-8Ipcie Card; How To Determine Which Controller Is In Your Server - Cisco UCS C250 Installation And Service Manual

Hide thumbs Also See for UCS C250:
Table of Contents

Advertisement

Appendix C
RAID Controller Considerations

Cisco UCS C250 Server Cabling

The cable connections required for each type of supported controller are as follows:

LSI SAS3081E-R PCIe Card

The required
cable 2 controls drives 5–8.

LSI MegaRAID SAS 9261-8iPCIe Card

The required
cable 2 controls drives 5–8.

How to Determine Which Controller Is in Your Server

If you do not have a record of which option is used in the server, you can disable quiet boot and read the
on-screen messages that are displayed during system bootup.
Information about the models of card installed are displayed as part of the verbose boot. You are also
prompted to press Ctrl-H to launch configuration utilities for those cards. For servers running CIMC
firmware earlier than release 1.2(1), see also
Than Release 1.2(1), page
OL-20888-02
cable kit has two mini-SAS cables. Cable 1 controls drives 1–4 and
R2XX-PL003-CBL
1.
Connect mini-SAS cable 1 from connector SAS1 on the controller to the SAS1 connector on the
backplane.
Connect mini-SAS cable 2 from connector SAS2 on the controller to the SAS2 connector on the
2.
backplane.
cable kit has two mini-SAS cables. Cable 1 controls drives 1–4 and
R2XX-PL003-CBL
Connect mini-SAS cable 1 from connector SAS1 on the controller to the SAS1 connector on the
1.
backplane.
Connect mini-SAS cable 2 from connector SAS2 on the controller to the SAS2 connector on the
2.
backplane.
C-4.
How to Determine Which Controller Is in Your Server
How to Disable Quiet Boot For CIMC Firmware Earlier