HE440A, HE480A STEAM POWER HUMIDIFIER
Table 2. Recommended Convertible Humidity
Control Settings.
Use
At Outside
This
Temperature
Setting
-20°F (-29°C)
15
-10°F (-23°C)
20
-0°F (-18°C)
25
The HE440A, HE480A Humidifiers use the principle that hot
water creates water vapor. As dry air and vapor mix, the
relative humidity of the air rises. The humidity control monitors
the relative humidity and activates the humidifier accordingly.
When the humidity control calls for humidity, the humidifier
underwater heater starts heating the water in the humidifier
reservoir. When the water is warm enough, the humidifier
activates a relay that turns on the furnace fan. The warm dry
air from the furnace picks up the water vapor and circulates it
through the home. The fan continues to circulate the air until
the water cools down and then turns off the fan.
Humidified air feels warmer and more comfortable so you may
be able to lower the thermostat heating setpoint and save
money on heating fuel bills to give you a more comfortable
environment that is also energy efficient.

MAINTENANCE

A regular maintenance program prolongs humidifier life and
provides a more comfortable environment. Frequency of filter
replacement depends on water conditions. Either hard or soft
water can be used in the water treatment system.
CAUTION
Voltage Hazard.
Can cause electrical shock and equipment
damage.
Unplug device to disconnect power supply before
installing or servicing.
IMPORTANT
Never oil any part of the humidifier.
Every Year - 3 to 6 Months of Operation
(Depending on Usage and Water Quality)
Use the following procedure and see Fig. 12 to replace the
chlorine filter.
IMPORTANT
Regularly replacing the chlorine filter protects the RO
filter.
68-0265EF-1
Use
At Outside
This
Temperature
Setting
+10°F (-12°C)
30
+20°F (-7°C)
35
Above 20°F
40
(-7°C)
1. Unplug the humidifier.
2. Replace chlorine filter. Use hand tool (provided) to
loosen housing.
NOTE:
Be sure gaskets on both ends of filter are
removed from housing with the old filter.
Be sure new gaskets (provided with filter) are
installed.
Every 2 to 3 Years (Depending on Usage and

Water Quality)

Use the following procedure and see Fig. 12 to replace both
chlorine filter and RO filter.
Fig. 12. Replacing filters.
IMPORTANT
Regularly replacing RO filter reduces the potential for
deposit buildup in the reservoir.
1. Unplug the humidifier.
2. Replace chlorine filter. Use hand tool (provided) to
loosen housing.
NOTE:
Be sure gaskets on both ends of filter are
removed from housing with the old filter.
Be sure new gaskets (provided with filter) are
installed.
3. Disconnect the tubing between the chlorine filter and
the reverse osmosis (RO) filter.
4. Unscrew the cap on the RO filter.
8
CHLORINE FILTER HAND TOOL
CHLORINE FILTER
RO FILTER
M20336A