Download Print this page

MULTIQUIP DCA400 Series Installation Instructions Manual page 4

Fuel return modification
Hide thumbs Also See for DCA400 Series:

Advertisement

inStAll neW return extenSion hoSe
Refer„to„Figure„9.
1.„ Connect„ Item„ 6,„ return„ extension„ hose,„ to„ item„ 4.„
Secure„with„clamp,„Item„5.
2.„ Install„Item„7,„straight„fitting,„between„extension„hose„
and„existing„engine„return„hose.„Secure„with„clamps.
6
5
4
Figure 9. New Return Extension Hose
3.„ Install„spiral„tubing,„Item„10,„around„return„extension„
hose.„Secure„with„cable„ties,„Item„9.„See„Figure„10.
DCA400 SerieS — Fuel return line kit inStruCtionS p/n 35499 — rev. #0 (01/26/11) — pAge 4
Engine
Return Hose
5
5
7
10
9
Figure 10. Spiral Tubing
inStAll neW vent hoSe
1.„ Connect„Item„8,„vent„hose,„to„generator„pick-up„port„and„
return„port.„Secure„with„clamps,„Item„5.„See„Figure„11.„
8
5
Pick-Up
Port
Figure 11. Vent Hose
9
5
Return
Port

Advertisement