Fuel return modification
Hide thumbs Also See for DCA400 Series:

Advertisement

DiSASSembly
Figure„2„illustrates„the„unit's„current„fuel„line„configuration.„
Pick-Up
Hose
Trailer
Fuel Tank
Figure 2. Current Fuel Line Configuration
NOTICE
Fuel„leaks„may„occur„when„disconnecting„hoses„and„
fittings.„Wipe„up„any„spilled„fuel„immediately.
1.„ Turn„fuel„shut-off„valve„to„the„OFF„position„(Figure„3).
Drain
Trailer
Fuel Tank
Figure 3. Fuel Shut-Off Valve (Off Position)
DCA400 SerieS — Fuel return line kit inStruCtionS p/n 35499 — rev. #0 (01/26/11) — pAge 2
Generator
Fuel Tank
Engine
Return
Hose
Drain
Fuel Shut-Off
Valve (OFF Position)
2.„ Disconnect„pick-up„hose„from„pick-up„port„and„discard.„ „
See„Figure„4.
Remove/Discard
Pick-Up Hose
Figure 4. Remove/Discard Pick-Up Hose
3.„ Disconnect„engine„return„hose„from„return„port.„See„
Figure„5.
Figure 5. Disconnect Engine Return Hose
Pick-Up
Port
Disconnect
Engine Return
Hose
Return
Port