Download Print this page

MULTIQUIP DCA400 Series Installation Instructions Manual page 3

Fuel return modification
Hide thumbs Also See for DCA400 Series:

Advertisement

4.„ Disconnect„ drain„ hose„ from„ trailer„ return„ port.„ See„
Figure„6.
Trailer
Return
Port
Figure 6. Disconnect Drain Hose
5.„ Remove„fittings„from„trailer„return„port.„Retain„the„90º„
fitting,„and„discard„the„others.„See„Figure„7.
Retain
90º Fitting
Remove
Fittings
Figure 7. Remove Trailer Return Port Fittings
DCA400 SerieS — Fuel return line kit inStruCtionS p/n 35499 — rev. #0 (01/26/11) — pAge 3
Drain
Disconnect
Drain Hose
Trailer
Return Port
inStAll neW trAiler return port FittingS
Refer„to„Figure„8.
4
Figure 8. New Trailer Return Port Fittings
NOTICE
Apply„pipe„sealant„to„all„fittings.
1.„ Install„Item„3,„tee„fitting,„into„trailer„return„port.
2.„ Install„Item„2,„straight„fitting,„into„the„right„side„of„the„
tee„fitting.
3.„ Install„existing„90º„fitting„into„Item„2.„Connect„to„drain„
hose.
4.„ Install„Item„4,„straight„fitting,„into„the„left„side„of„the„tee.
3
2
Drain
Hose
Existing 90º
Fitting