Optional installation over GE undersink dishwasher
model GSM 2100.
Read these instructions completely and carefully.
Dimensions and Clearances for Optional Installation
J
1
3
clearance to
side wall
This counter unit must be installed with the control
knobs toward the front edge of the countertop.
Counter space must be provided for installation of
the counter unit. When choosing the location of the
cooktop and dishwasher, consider the following:
I When installing over a dishwasher, cooktop
models JP200 and JP201 are only approved for
installation over GE Undersink Dishwasher
model GSM2100. Install the dishwasher using
the separate installation instructions packed
with the dishwasher.
I The cooktop should be easy to reach and
lighted with natural light during the day.
I To eliminate the risk of burns or fire by
reaching over heated surface units, cabinet
storage space located above the surface units
should be avoided. If cabinet storage space
is to be provided, the risk can be reduced by
installing a range hood that projects
horizontally a minimum of 5" beyond the
bottom of the cabinets. Cabinets installed
above the counter unit may be no deeper than
13" and must be at least 30" above the cooktop.
12
(if not installing the cooktop over a dishwasher, go to the next page)
13"
Max.
A
C
D
F
E
" Min.
4
Unit and cutout dimensions
"
A: 21
1
B: 16
4
"
F: 20
1
G: 10
30" Min.
8
H
B
" Min.
1
3
4
clearance to
side wall
K
G
36"
Floor
I The cooktop must be centered left to right over
the dishwasher unit.
I To insure accuracy, it is best to make a template
when cutting the opening in the counter. See
the illustration and chart above for all necessary
dimensions.
The following minimum clearances must be
maintained:
I 3
" minimum clearance between the front
3
4
edge of the counter unit and the front edge of
the counter.
I 30" minimum vertical clearance from the
cooktop to the nearest overhead surface.
I 18" minimum vertical clearance to adjacent
cabinets.
"
"
"
5
C: 19
15
D: 15
15
8
16
16
"
H: 3 "
J: 2 " Min.
1
16
"
E: 16
1
8
" Min.
K: 3
3
4

Advertisement