TROUBLESHOOTING

ProblemPossible Cause/Remedy
• Travel Cooler/Warmer is not functioning as cooler or warmer (fan is not turning)
• Accessory outlet of DC power supply is not functioning -check by plugging in a
12VDC appliance. If not, clean accessory outlet and re-connect the Travel
Cooler/Warmer.
• Fuse or circuit breaker in accessory outlet is open. Reset breaker or check fuse, and
replace fuse if necessary.
• Ignition is switched off - start engine or switch ignition to accessory position.
• Fuse in unit's power cord is blown - see Fuse Replacement section for location of
fuse and instructions for checking and replacing fuse.
- Cooler/warmer is not cooling or heating properly (fan is not turning).
• Fan
is
defective. Call Vector®
return/replacement instructions. This unit is not user-serviceable, it must be
returned to Vector Manufacturing for professional service or repair. Any attempt
to service by user will void warranty..
- Cooler/warmer is not cooling or heating, but fan is turning
• Cooling unit is defective. Call Vector® Customer Service department for
return/replacement instructions. This unit is not user-serviceable, it must be
returned to Vector Manufacturing for professional service or repair. Any attempt
to service by user will void warranty..
- Travel Cooler/Warmer takes longer than 30 minutes to reach design inside
temperature
• Low battery or supply voltage.
• Unit will attain design temperature more efficiently if items are pre-heated or pre-
chilled.
• Fan area is blocked - Move unit or object

SPECIFICATIONS:

Capacity . . . . . . . . . . . . . 7 Liter / 1.85 Gallons (US)
Power Supply: . . . . . . . . . 12-volt DC
Power Cord: . . . . . . . . . . 7', with accessory outlet-type plug and 10 Amp fuse
Amperage draw: . . . . . . . 3.5 Ampers (approx. 42-watts)
Cooling Performance: . . . Cools to average 40ºF below surrounding air (4.41ºC)
Warming Performance: . . Warms to 120°F (54.41ºC) above surrounding air.
High Temperature Limit: . . Automatic ON/OFF.
Cold/Heat Transfer: . . . . . Temperature-efficient, aluminum-coated liner
Insulation: . . . . . . . . . . . . CFC-free polyurethane liner
Heat Dissipation: . . . . . . . Built-in fan with long-life, brushless motor
Warm/Cool System: . . . . Non-wearing thermoelectric