LENNOX HEARTH PRODUCTS • CRESTLINE™ SERIES B-VENT GAS FIREPLACES • 36"/42" LSBV MODELS • CARE AND OPERATION INSTRUCTIONS
OPTIONAL gLASS DOOR
7. Clean the optional glass doors only when
necessary. Wipe surface with clean, damp-
ened, soft cloth. Follow with dry, soft towel
as desired. Take care not to scratch the glass
surface.
CAUTION: ALWAYS USE DOOR HANDLES.
DOORS WILL BECOME VERY HOT WHEN
FIREPLACE IS IN USE.
WARNINg
• Do not attempt to substitute
the materials used on doors,
or replace cracked or broken
glass.
• Handle this glass with
extreme care! glass is sus-
ceptible to damage – Do not
scratch or handle roughly
while reinstalling the glass
door frame.
• The glass doors of this appli-
ance must only be replaced
as a complete unit as pro-
vided by the manufacturer.
Do not attempt to replace
broken, cracked or chipped
glass separately.
• Do not attempt to touch the
glass doors with your hands
while the fireplace is in use.
• Do not operate appliance with
the glass doors cracked or
broken.
• Do not use abrasive cleaners.
Never clean the glass when
it is hot.
• Fireplaces equipped with
optional accessory doors
should be operated only
with the doors fully open or
fully closed (Figure 4). This
appliance may only be fitted
with doors certified for use
with the appliance.
8
WARNINg
Only doors certified with the
appliance shall be used.
AVERTISSEMENT
Pour utilisation uniquement
avec les portes en verre certi-
fiêes avec l'appareil.
Fully Open or
Fully Closed
Figure 4 - Optional Glass Doors
DAMPER AND OUTSIDE AIR CONTROLS
This appliance is fitted with a manually controlled
vent damper. The vent damper should be closed
when the appliance is not in use to prevent cold
air from entering the home through the venting
system. The damper is controlled through the
use of a control lever located within the appli-
ance opening at the top center in front of the
firebox lintel (see Figure 5). The control lever
snaps into place at either extreme of its range
of motion. When locked in position all the way
to the right, the damper is open. When locked
in position all the way to the left, the damper
is closed.
The damper lever actuates a switch, (see wiring
diagram) which will prevent the appliance main
burner from lighting unless the damper is locked
open. The appliance flue damper must always
remain open when operating.
WARNINg
Do not operate the shutoff lever
unless a complete outside air
vent system has been installed
with your appliance.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
WARNINg
Damper must be in open position
when appliance main burner is
operating.
AVERTISSEMENT
Le registre doit être en position
ouverte lorsque le ou les bru-
leurs principaux de l'appereil
fonctionnment.
Locked
Closed
Locked
Open
Outside Air
Actuator
Figure 5
The appliance is equipped with an outside
(make-up air) vent system that is designed to
provide the appliance with outside make-up air
for combustion when in operation. The shut-
off lever for the outside air system is standard
on all appliances but should not be operated
if the complete system is not installed. Refer
to Figure 5. Outside air kits are not required
in all municipalities and may not be installed
or active with your appliance.
If you have reason to believe that you do
not have a complete outside air system, con-
tact your distributor to have your appliance
inspected for the presence of the complete
system. DO NOT assume that you have this
system in place.
The hand operated shut-off lever is located in
the right side of the fireplace opening behind
the screen. To open, lift and pull all the way.
The outside air damper should be open when
the fireplace is in use and completely closed
when the fireplace is not being used. This
will prevent outside cold air from entering
the dwelling.