Vanguard MINI-HEARTH VMH2800TPC Owner's Operating & Installation Manual

Vent-free propane/lp gas heater 14,000 to 28,000 btu/hr with thermostat “c” models

Advertisement

VENT-FREE PROPANE/LP GAS
MINI-HEARTH
OWNER'S OPERATION AND INSTALLATION MANUAL
®
14,000 to 28,000 Btu/Hr with Thermostat "C" Models
WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result caus-
ing property damage, personal injury, or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's in-
structions.
• If you cannot reach your gas supplier, call the
fire department.
— Installation and service must be performed by a
qualified installer, service agency, or the gas supplier.
This appliance may be installed in an aftermarket* manufactured (mobile) home,
where not prohibited by state or local codes.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer. (I.E.
Installation of this product is permitted after the manufactured (mobile) home is sited)
This appliance is only for use with the type of gas indicated on the rating plate.
This appliance is not convertible for use with other gases.
VMH2800TPC
Save this manual for future reference.
®
®
HEATER
Shown With Optional Mantel
Which Features a Built In Base
WARNING: Improper installation,
adjustment, alteration, service,
or maintenance can cause injury
or property damage. Refer to this
manual for correct installation
and operational procedures. For
assistance or additional infor-
mation consult a qualified in-
staller, service agency, or the
gas supplier.
WARNING: This is an unvented
gas-fired heater. It uses air (oxy-
gen) from the room in which it is
installed. Provisions for adequate
combustion and ventilation air
must be provided. Refer to Air for
Combustion and Ventilation sec-
tion in this manual.

Advertisement

Table of Contents
loading

Summary of Contents for Vanguard MINI-HEARTH VMH2800TPC

  • Page 1 ® Shown With Optional Mantel Which Features a Built In Base 14,000 to 28,000 Btu/Hr with Thermostat “C” Models VMH2800TPC WARNING: Improper installation, WARNING: If the information in this manual is not adjustment, alteration, service, followed exactly, a fire or explosion may result caus- or maintenance can cause injury ing property damage, personal injury, or loss of life.
  • Page 2: Safety Information

    ® GAS RESIDENTIAL HEATERS SAFETY If you smell gas person should service and repair heater. • shut off gas supply 15. Operating heater above elevations of INFORMATION • do not try to light any appliance 4,500 feet could cause pilot outage. •...
  • Page 3: Product Identification

    OWNER’S MANUAL PRODUCT Control Knob Ignitor Button IDENTIFICATION Lighting and Warning Plates Heater Screen Cabinet Front Panel Figure 1 - Vent-Free Gas Log Propane/LP Gas Space Heater Piezo Ignitor UNPACKING Ignitor Cable 1. Remove heater from carton. Remove all protective packaging ap- plied to heater for shipment.
  • Page 4 ® GAS RESIDENTIAL HEATERS ASSEMBLY Heater Cabinet Top Brass Side Adjusting Trim Continued Brass Plate Deflector Trim Screws Front Panel Retaining Screen Shim Brackets Slot Mitered Edge Slot Truss- Figure 6 - Assembling Brass Trim Head Screw 6. While firmly holding edges of brass trim together, tighten both set screws on the adjusting plate with slotted screwdriver.
  • Page 5: Fresh Air For Combustion And Ventilation

    OWNER’S MANUAL FRESH AIR FOR PROVIDING ADEQUATE Confined and Unconfined Space VENTILATION COMBUSTION AND The National Fuel Gas Code (ANSIZ223.1, 1992 Section 5.3) defines a confined space The following is exerpts from National Fuel VENTILATION as a space whose volume is less than 50 Gas Code.
  • Page 6 ® GAS RESIDENTIAL HEATERS AIR FOR COMBUSTION AND VENTILATION Continued DETERMINING AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.
  • Page 7: Air For Combustion And Ventilation

    OWNER’S MANUAL AIR FOR COMBUSTION AND VENTILATION Continued 12" WARNING: If the area in which the heater may be operated is smaller than that defined as an Ventilation Grills unconfined space, provide ad- Into Adjoining Room, Ventilation Option 2 equate combustion and ventila- Grills tion air by one of the methods into Adjoining...
  • Page 8: Check Gas Type

    ® GAS RESIDENTIAL HEATERS INSTALLATION IMPORTANT: Vent-free heaters add mois- WARNING: Never install the ture to the air. Although this is beneficial, heater installing heater in rooms without enough NOTICE: A qualified service per- • in a bedroom or a bathroom ventilation air may cause mildew to form from son must install heater.
  • Page 9 OWNER’S MANUAL THERMOSTAT SENSING INSTALLATION OPTIONS Marking Screw Locations BULB Tape mounting bracket to wall where There are three options for mounting this heater will be located. Make sure heater. The thermostat sensing bulb has been placed mounting bracket is level. inside the heater for protection during shipping.
  • Page 10 ® GAS RESIDENTIAL HEATERS INSTALLATION Placing Heater On Mounting Tighten both screws until heater is firmly secured to wall. Do not over Bracket Continued tighten. 1. Locate two horizontal slots on back Do not replace front panel at this Note: Attaching to wall anchor method panel of heater.
  • Page 11 OWNER’S MANUAL Bottom of Heater INSTALLATION Base Shipping Screw Continued Note: It is an option to secure “A” model hearth base to floor. You must secure the “B” and “C” model hearth base to floor. To secure hearth base to floor, follow instructions under Securing Hearth Base to Floor, below.
  • Page 12: Connecting To Gas Supply

    ® GAS RESIDENTIAL HEATERS CONNECTING TO CAUTION: Use only new, CAUTION: Use pipe joint seal- GAS SUPPLY black iron or steel pipe. Inter- ant that is resistant to liquid pe- nally-tinned copper tubing may troleum (LP) gas. be used in certain areas. Check NOTICE: A qualified service per- your local codes.
  • Page 13: Checking Gas Connections

    OWNER’S MANUAL CHECKING GAS 3. Check all joints from propane/LP sup- Check all joints from manual shutoff ply tank to manual shutoff valve (see valve to thermostat gas valve (see Fig- CONNECTIONS Figure 23). Apply mixture of liquid ure 23). Apply mixture of liquid soap soap and water to gas joints.
  • Page 14: Operating Heater

    ® GAS RESIDENTIAL HEATERS OPERATING Keep control knob pressed in for 30 LIGHTING seconds after lighting pilot. After 30 HEATER INSTRUCTIONS seconds, release control knob. • If control knob does not pop up FOR YOUR SAFETY STOP! Read the safety information when released, contact a qualified above.
  • Page 15: Inspecting Burner

    OWNER’S MANUAL OPERATING If pilot flame pattern is incorrect, as MANUAL shown in Figure 27 HEATER LIGHTING • turn heater off (see To Turn Off Gas Continued PROCEDURE to Appliance). • see Troubleshooting, pages 17 TO TURN OFF through 19. 1.
  • Page 16: Cleaning And Maintenance

    ® GAS RESIDENTIAL HEATERS INSPECTING CLEANING AND BURNER MAINTENANCE Continued WARNING: Turn off heater and let cool before cleaning. Top of Flame CAUTION: You must keep About One control areas, burner, and circu- Inch Above lating air passageways of heater clean.
  • Page 17: Trouble Shooting

    OWNER’S MANUAL TROUBLE WARNING: Turn off and unplug heater and let cool before servicing. SHOOTING Only a qualified service person should service and repair heater. Note: All Trouble Shooting items are listed in order of operation. CAUTION: Never use a wire, needle, or similar object to clean ODS/ pilot.
  • Page 18 ® GAS RESIDENTIAL HEATERS TROUBLE SHOOTING Continued POSSIBLE CAUSE OBSERVED PROBLEM REMEDY 1. Burner orifice is clogged Burner does not light after ODS/pilot is lit 1. Clean burner (see Cleaning and Maintenance, page 16) or replace burner orifice 2. Burner orifice diameter is too small 2.
  • Page 19: Technical Service

    OWNER’S MANUAL TROUBLE SHOOTING Continued Operating heater where im- IMPORTANT: WARNING: If you smell gas purities in air exist may create odors. Clean- • Shut off gas supply. ing supplies, paint, paint remover, cigarette • Do not try to light any appliance. smoke, cements and glues, new carpet or •...
  • Page 20: Replacement Parts

    ® GAS RESIDENTIAL HEATERS REPLACEMENT ACCESSORIES PARTS Purchase these heater accessories from your local dealer. If they can not supply these Use only original replacement parts. Note: accessories call DESA International’s Sales This will protect your warranty coverage for Department at 1-800-458-2472 for infor- parts replaced under warranty.
  • Page 21 OWNER’S MANUAL ACCESSORIES Continued GS601 - Black Surround For locating heater in front of an existing fireplace. The sturdy steel construction is accented with decorative brass trim. Com- plete installation instructions included. PREMIER MANTEL Unfinished - GM903U Series Finished - GM902F Series For use with heater.
  • Page 22 ® GAS RESIDENTIAL HEATERS 12-1 12-2 103507...
  • Page 23: Parts List

    OWNER’S MANUAL PARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 20 of this manual. VMH2800TPC PART NO. DESCRIPTION QTY. 098304-01 Screw, #10 x 3/8" 100566-01CK...
  • Page 24: Warranty Information

    WARRANTY INFORMATION KEEP THIS WARRANTY Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty.

Table of Contents