Operating Heater; For Your Safety Read Before Lighting; Lighting Instructions - Vanguard MINI-HEARTH VMH2800TPC Owner's Operating & Installation Manual

Vent-free propane/lp gas heater 14,000 to 28,000 btu/hr with thermostat “c” models
Table of Contents

Advertisement

GAS RESIDENTIAL HEATERS
OPERATING
HEATER
FOR YOUR SAFETY
READ BEFORE
LIGHTING
WARNING: If you do not fol-
low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.
A. This appliance has a pilot which must
be lighted by hand. When lighting the
pilot, follow these instructions ex-
actly.
B. BEFORE LIGHTING smell all
around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch;
do not use any phone in your
building.
• Immediately call your gas supplier
from a neighbor's phone. Follow
the gas supplier's instructions.
• If you cannot reach your gas
supplier, call the fire department.
C. Use only your hand to push in or turn
the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don't try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.
D. Do not use this appliance if any part
has been under water. Immediately
call a qualified service technician to
inspect the appliance and to replace
any part of the control system and
any gas control which has been un-
der water.
®
INSTRUCTIONS
1.
STOP! Read the safety information
above.
2.
Make sure manual shutoff valve is
fully open.
3.
Turn control knob clockwise
to the OFF position.
Ignitor Button
IGNITOR
Figure 24 - Control Knob In The OFF
Position
4.
Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow "B" in the safety in-
formation at the top of page 23. If you
don't smell gas, go to the next step.
5.
Turn control knob counterclockwise
C-clockwise
in control knob for five (5) seconds
(see Figure 24).
Note:
heater for the first time after
hooking up to gas supply. If so, the
control knob may need to be
pressed in for 30 seconds. This will
allow air to bleed from the gas
system.
6.
With control knob pressed in, push
down and release ignitor button. This
will light pilot. The pilot is attached
to the front of burner. If needed, keep
pressing ignitor button until pilot
lights.
Note:
to Troubleshooting, pages 17
through 19. Also contact a
qualified service person or gas
supplier for repairs. Until repairs
are made, light pilot with match.
To light pilot with match, see
Manual Lighting Procedure, page 15.
LIGHTING
Control Knob
to the PILOT position. Press
You may be running this
If pilot does not stay lit, refer
14
7.
Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
• If control knob does not pop up
when released, contact a qualified
service person or gas supplier for
repairs.
Note:
If pilot goes out, repeat steps
3 through 7. This heater has a
safety interlock system. Wait one
(1) minute before lighting pilot
again.
Ignitor Electrode
Thermocouple
Figure 25 - Pilot
8.
Turn control knob counterclockwise
to desired heating level. The
C-clockwise
main burner should light. Set control
knob to any heat level between HI
and LO.
CAUTION: Do not try to adjust
heating levels by using the
manual shutoff valve.
Pilot Burner
103507

Advertisement

Table of Contents
loading