Product Identification; Local Codes - Comfort Glow (VENT-FREE) GAS STOVE HEATER Owner's Operating & Installation Manual

(vent-free) gas stove heater
Table of Contents

Advertisement

SAFETY INFORMATION
Continued
4. This heater shall not be installed in a bedroom
or bathroom.
5. Do not place stove directly on carpeting,
vinyl tile or any combustible material other
than wood. The stove must set on a metal
or wood panel extending the full width and
depth of the appliance.
6. Do not use this stove as a wood burning fire-
place. Use only model SL30PT or SL30NT
vent-free gas log heater.
7. Do not add extra logs or ornaments such as pine
cones, vermiculite or rock wool. Using these
added items can cause sooting.
8. This log heater is designed to be smokeless. If
logs ever appear to smoke, turn off heater and
call a qualified service person. Note: During
initial operation, slight smoking could occur
due to log curing and heater burning manu-
facturing residues.
9. To prevent the creation of soot, follow the
instructions in Cleaning and Maintenance,
page 17.
10. Before using furniture polish, wax, carpet
cleaners or similar products, turn heater off.
If heated, the vapors from these products may
create a white powder residue within burner
box or on adjacent walls or furniture.
11. This heater needs fresh, outside air ventilation
to run properly. This heater has an Oxygen De-
pletion Sensing (ODS) safety shutoff system.
The ODS shuts down the heater if not enough
fresh air is available. See Air for Combustion
and Ventilation, page 5. If heater keeps shutting
off, see Troubleshooting, page 18.
12. Do not run heater
• where flammable liquids or vapors are used
or stored
• under dusty conditions
13. Do not use this stove to cook food or burn paper
or other objects.
14. Do not use heater if any part has been exposed
to or under water. Immediately call a qualified
service technician to inspect the room heater
and to replace any part of the control system and
any gas control which has been under water.
15. Do not operate heater if any log is broken. Do
not operate heater if a log is chipped (dime-
sized or larger).
4
16. Turn heater off and let cool before servicing.
Only a qualified service person should service
and repair heater.
17. Operating heater above elevations of 4,500
feet could cause pilot outage.
18. To prevent performance problems, the use of a
propane/LP tank of less than 100 lb. capacity is
not recommended (propane/LP units only).
19. Provide adequate clearances around air
openings.
Stove
Body
One Piece
Log Set
Inside Stove
Cavity
Stove Door (Shown
in the open position)
Figure 1 - Typical Stove Cabinet Model
with Comfort Glow Gas Log Heater
www.desatech.com
PRODUCT
IDENTIFICATION
Piezo
Ignitor
Control
Knob
115580-01A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sl30pt seriesSl30nt series

Table of Contents