Programming A Button To Increment/Decrement A Program Change - M-Audio Oxygen 88 User Manual

Table of Contents

Advertisement

30
User Guide

Programming a Button to
It is possible to configure a button to send an Increment (increase) or Decrement (decrease) Program Change
message each time it is pressed.
To configure a button to increment a Program Change between a minimum and maximum value, assign the button to
number 156 (see "Assignable MIDI CCs" on page 41). The minimum and maximum values are set using the Data 2 and
Data 3 parameters respectively.
The requires three values to be specified (values given are examples):
Key
Control Assign
Data 2 (example)
Data 3 (example)
The following example configures a button to increment through the sound patches on a connected software or
hardware synthesizer:
1. Select the Control as described earlier in this guide (Button or Pedal).
2. Press the Advanced button.
3. Press the Control Assign key.
4. Enter 156 using the number keys. This configures the button to increment the Program number.
5. Press the Enter key.
6. Press the Advanced button.
7. Press the Data 2 key.
8. Enter 0 using the number keys. This specifies the lowest Program number.
9. Press the Enter key.
10. Press the Advanced button.
11. Press the Data 3 key.
12. Enter 127 using the number keys. This specifies the highest Program number.
13. Press the Enter key.
To configure a button to decrement a Program Change between a maximum and minimum value, assign the button to
number 155 (see "Assignable MIDI CCs" on page 41). The minimum and maximum values are set using the Data 2 and
Data 3 parameters respectively.
NOTE: Each button will only increment or decrement its own parameter value and this value is independent of any
other button. In other words, assigning one button to increment through sound patches and another button to
decrement through sound patches will cause the first button to recall programs 1, 2, 3, etc., each time the button is
pressed. Pressing the second button will recall programs such as 127, 126, 125 (as opposed to starting to decrement
where the first button left of; for example 2, 1, 0).
Increment/Decrement
Parameter
Program Increment
Program Number (minimum)
Program Number (maximum)
a Program Change
Value
156
0
127
Oxygen 88