TROUBLE/ INDICATION
Low battery alarm
sounds continuously
Low battery
alarm sounds
Motorized power tool
Motorized power tool
does not operate at
correct speed
Television/Radio
interference
9.

FUSE REPLACEMENT

If external fuses blow, (or breakers trip), then there is a short or overload
in the DC wiring. Find and fix the problem before replacing the fuses
(or resetting the breaker). After fuse replacement, reconnect the inverter.
This power inverter is equipped with multiple internal fuses. Normally,
these fuses will not blow unless there is a serious problem inside the unit.
Internal fuses are replaceable, however, only electronically knowledgeable
people should attempt fuse replacement. If the unit is damaged during fuse
replacement, the warranty may be voided. Husky recommends contacting
Technical Support for guidance. Based on experience, it is best to return
the unit to Husky for repair. Husky Technical Support can be reached
by calling 954-584-4446, extension 19.
POSSIBLE CAUSE
Bad connection or wiring
Low battery voltage
Excessive start-up load
won't start
Purely inductive load
Snow in picture, buzz
in speaker
SUGGESTED REMEDY
Tighten all DC
connections
Recharge battery.
Remove load from
inverter while recharging
battery
If appliance does not start,
then appliance is drawing
excessive wattage and will
not work with inverter
Make the load not purely
inductive. Operate an
incandescent lamp at
same time as motor
Keep inverter and
antenna distant from
each other. Use shielded
antenna cable. Connect
antenna to amplifier
13