Download Print this page

Options And Accessories - Panasonic MDF-U33V Specifications

Vip series -86°c ultra-low freezers

Advertisement

VIP
Series Door Configuration
®
Maximum Sample Storage Capacity
Description
Model Number
Individual Storage Rack System
Microplate Storage Racks
(Plates Not Included)
Inventory Rack for Microplates, with locking rod;
108 Standard Plates with Cover Lid Per Rack
Inventory Rack for Microplates, with locking rod;
96 Standard Plates with Cover Lid Per Rack
Inventory Rack for Microplates, with locking rod;
60 Standard Plates with Cover Lid Per Rack
Fiberboard Storage Boxes and Dividers
Inventory Box, 2" high (2ml sample)
with 100-Cell Divider
Inventory Box, 3" high (4ml sample)
with 100-Cell Divider
Inventory Box, 2" high (2ml sample)
without Divider
Inventory Box, 3" high (4ml sample)
without Divider
Box Divider, 81-Cell
Box Divider, 64-Cell
Options & Accessories
Water Cooled Option Features
Water Pressure & Temperature
Connections
Required Water Flow Rate
(Maximum)
Installation
Accessory
Half Inner Door
Digital Temperature Recorder
Liquid CO
Back-Up System
2
Liquid N
Back-Up System
2
Chart Recorder
Chart Paper
Replacement Pen, Red / Blue
Digital Touch Panel Recorder
Data Logging Software
21 CFR Part 11 Compliant Software
MDF-U33V-PA
MDF-U53VA-PA
Catalog Number
Catalog Number
SUMPR-612-LR
SUMPR-612-LR
Capacity 6
SUMPR-611-LR
SUMPR-616-LR
Capacity 6
B2C-S100
B3C-S100
B2C
B3C
D81
D64
Maximum Water Pressure: 150psig, Minimum Water Pressure Differential: 15psig, Maximum Water Temperature: 30°C
Typically ½" compression fittings on inlet and outlet but can be customized for customer needs
Qualified technician required at time of installation to balance water flow requirements. Efficiencies can be easily obtained
regarding water usage by balancing the water flow to optimum usage and freezer efficiency dependent upon the specific site
Description
Set of two; Field Installed; replaces half inner door;
for a four-door configuration order two sets
Auxiliary Data Logger
Auxiliary tank back in event of power failure
Auxiliary tank back in event of power failure
Circular Chart Temperature Recorder, 7 Day
6" Diameter, 7 Day Chart
Felt tip pens, 6 per pack
Programmable digital temperature recorder
For use with touch panel recorder
For use with touch panel recorder
MDF-U56VC-PA
Catalog Number
SUMPR-612-LR
Capacity 8
Capacity 8
SUMPR-611-LR
Capacity 8
Capacity 8
B2C-S100
B2C-S100
B3C-S100
B3C-S100
B2C
B2C
B3C
B3C
D81
D81
D64
D64
Description
Tower Water: 11.4 liters per minute
installation
MDF-5ID-PW (MDF-U53VA), MDF-5ID1-PW (MDFU-56VC),
MDF-7ID1-PW (MDF-U76VC / MDF-U76VA)
MDF-U76VC-PA
MDF-U76VA-PA
Catalog Number
Catalog Number
SUMPR-612-LR
SUMPR-612-LR
Capacity 24
Capacity 24
B2C-S100
B2C-S100
B3C-S100
B3C-S100
B2C
B2C
B3C
B3C
D81
D81
D64
D64
Catalog Number
HAMSTERDT2
CVK-UB2(I)-PW
CVK-UBN2-PW
MTR-C954
C7100386REV
R252 / R253
FT560SN
A016
A026
11

Advertisement

loading

This manual is also suitable for:

Mdf-u53vaMdf-u76vcMdf-u76vaMdf-u56vc