GE JBC16GP Use, Care & Installation Manual page 26

Standard clean models; continous clean models
Hide thumbs Also See for JBC16GP:
Table of Contents

Advertisement

STEP
2
PREPARE FOR ELECTRICAL CONNECTION
Use only a 3-conductor, or if required a 4-
conductor range
cord set as noted
below.
These
cord sets are provided
with ring
type terminals.
The electrical rating of the cord must be
125/250 volts minimum, 40 amperes.
NOTE:
Only a 4-conductor cm-d is to be used
when the appliance is installed in a mobile
home or where local codes do not permit
grounding through the neutral.
STEP 3
1. Locate connector block at the bottom rear
of range and remove rear wiring cover.
2. Directly below the connector block is a
hole with a knockout ring for accommodating
conduit fittings. Brackets provided are used to
support the flexible cord strain relief, which
must be securely attached to the cord set.
WIRING COVER
J
P
(SHOWN REMOVED)
:~+l#~CTOR
STRAIN RELIEF
BRACKETS
\
(PROVIDED
WITH
RANGE CORD SET.
!
NOT PART OF RANGE.)
dfs$!i?
* . - .
/"*\
a?
2
\vl/
.
":
STEP 4
I
HIRE
SYSTEM
4 +
.
Power Cord Installation-Insert
screws
through power cord terminals so that the
screws pass through connector block terminals
and engage nuts. Tighten screws securely.
SCREW +
POWER CORD
RING TERMINAL
&k
6
&
+-
POWER
CORD
:X#l~CTOR
/
49-
h4::ABLE
TERMINAL
I
Cable I)irect Installation-Clamp
bare wires
between the connector block terminals and
movable nuts with screws tightened securely.
1. Copper Wiring
Connect the neutral or grounded wire of the
supply circuit to the neutral terminal of the
connector block, located in the center. The
power leads must be connected to the outside
(brass colored) terminals.
GROUNDING
STRAP
(GROUNDED
TO RANGE)
26

Advertisement

Table of Contents
loading

Table of Contents

Save PDF