GE Café 30" Free-Standing Gas Range
Dimensions and Installation Information (in inches)
You must use the rear filler strip kit shipped with
the range or the optional accessory backguard
when installing these ranges
Note: Cabinets installed adjacent to slide-in
ranges must have an adhesion spec of at least
194° temperature rating.
Installation Information: Before installing, consult
installation instructions packed with product for
current dimensional data.
For answers to your Monogram,
GE Profile
®
GE
®
appliance questions, visit our website at
ge.com or call GE Answer Center
®
800.626.2000.
37-1/4"
30" Slide-In Range
Dimensions (in inches)
30" Min.
or
15" Min.
service,
30
4-1/2
6
5
2-1/4
Acceptable
Electrical
Outlet Area
*Wall to front of
37-1/4"
26-1/4"
30"
46-3/8"
36-1/4"
30" Slide-In Range
Dimensions (in inches)
26-1/4"
30" Slide-in Elec. Range
46-3/8"
Aug. 8, 2003 -km
30" Min.
15" Min.
Recommended
30
area for 120V outlet
4-1/2
on rear wall and
6
area for thru the
wall connection
5
of pipe stub and
shut-off valve
2-1/4
Acceptable
Electrical
Maintain
Outlet Area
at least 6"
from nearest
combustible
*Wall to front of
6
surface.
closed door handle
on model JSP34.
28" on models
45-1/8
31-1/2
JSP26/JSS26/16.
Note: Range may be placed with 0" clearance (flush) at the back wall and side walls
below countertop if the range side trims above the countertop extend beyond the cabinet
fronts at least 1/4". (Self-clean models only.) Maintain at least 6" distance from nearest
combustible surface.
+ _
36-1/4"
1/4
30" Slide-in Elec. Range
Aug. 8, 2003 -km
4
4
+ _
1/4
Recommended
area for 120V outlet
on rear wall and
area for thru the
wall connection
of pipe stub and
shut-off valve
30
Maintain
9
at least 6"
4
from nearest
4
combustible
Recommended area
6
surface.
for thru the floor
connection of pipe stub
and shut-off valve
24
31-1/2
Counter Cutout Dimensions (in inches)
13
If you are NOT using the
Filler strip or Backguard:
2
36
14-1/2
9
23-3/16
Recommended area
for thru the floor
connection of pipe stub
28-1/4*
30
and shut-off valve
30
All GE ranges are equipped with
an Anti-Tip device. The installation
If you are using the
of this device is an important,
required step in the installation
Filler strip or Backguard:
of the range.
36
Specification Revised 12/07
25
Recommended common
area for gas outlet and
electrical outlet
30
24
13
If you are NOT using the
Recommended common
Filler strip or Backguard:
area for gas outlet and
electrical outlet
2
2-1/2
14-1/2
23-3/16
30
If you are using the
Filler strip or Backguard:
2-1/2
25
30
230151

Advertisement

loading

Summary of Contents for GE Café CGS980SEMSS

  • Page 1 JSP26/JSS26/16. 4-1/2 Note: Range may be placed with 0" clearance (flush) at the back wall and side walls below countertop if the range side trims above the countertop extend beyond the cabinet fronts at least 1/4". (Self-clean models only.) Maintain at least 6" distance from nearest 2-1/4 combustible surface.