5-1. Front Panel Controls (Non-CE Models)

1
Output Control Switch
For weld output, place switch in On position.
For remote control of output, make connec-
tions to terminal strip TE3 or Remote 14 re-
ceptacle (see Section 3-12) and place switch
in Remote position.
2
A/V (Amperage/Voltage) Control Switch
For front panel control, place switch in Panel
position and use the A/V Adjust control.
!
Turn Off power before connecting re-
mote device.
OM-2221 Page 30
SECTION 5 − OPERATION
For remote control, connect remote device to
terminal strip TE3 or Remote 14 receptacle,
and place switch in Remote position. Remote
control provides full range of unit output re-
gardless of A/V Adjust control setting
3
Pilot Light
4
Power Push Button Switch
.
The fan motor is thermostatically
controlled and only runs when cooling is
needed.
5
High Temperature Shutdown Light
Lights if welding power source overheats.
1
2
6
6
A/V (Amperage/Voltage) Adjustment
Control
Use control to select weld voltage or amper-
age. Control may be adjusted while welding.
Numbers on scale are for reference only.
7
CC/CV Switch (Mounted Inside Access
Area)
!
Turn Off welding power source before
opening access door to change switch
position.
Place switch in desired position.
3
5
CC
CV
7
4
Ref. 175 086 / Ref. 801 882-A