Adjustment - Kenwood TK-3202 Service Manual

Uhf fm transceiver
Hide thumbs Also See for TK-3202:
Table of Contents

Advertisement

TK-3202/3206
Test Equipment Required for Alignment
Test Equipment
1.
Standard Signal Generator
(SSG)
2.
Power Meter
3.
Deviation Meter
4.
Digital Volt Meter
(DVM)
5.
Oscilloscope
6.
High Sensitivity
Frequency Counter
7.
Ammeter
8.
AF Volt Meter
(AF VTVM)
9.
Audio Generator (AG)
10.
Distortion Meter
11.
Spectrum Analyzer
12.
Tracking Generator
13.
8Ω Dummy Load
14.
Regulated Power Supply
The following parts are required for

adjustment

1. Antenna connector adapter
The antenna connector of this radio uses an SMA terminal.
Use an antenna connector adapter [SMA(f) – BNC(f) or
SMA(f) – N(f)] for adjustment. (The adapter is not provided as
an option, so buy a commercially-available one.)
2. Repair Jig (Chassis)
Use jig (part No.: A10-4086-03) for repairing the TK-3202/
3206. Place the TX-RX unit on the jig and fit it with screws.
The jig facilitates the voltage check and protects the final
amplifier FET when the voltage on the flow side of the TX-RX
unit is checked during repairs.
3. Battery Jig (W05-1011-00)
24
ADJUSTMENT
Frequency Range
450 to 490MHz (TK-3202(K, M) TK-3206(M) ) 470 to 512MHz (TK-3202(K2, M2) )
400 to 430MHz (TK-3206(M3) )
Modulation
Frequency modulation and external modulation.
Output
-127dBm/0.1µV to greater than -47dBm/1mV
Input Impedance
50Ω.
Operation Frequency
450 to 490MHz (TK-3202(K, M) TK-3206(M) ) 470 to 512MHz (TK-3202(K2, M2) )
400 to 430MHz (TK-3206(M3) )
Measurement Range
Vicinity of 10W
Frequency Range
450 to 490MHz (TK-3202(K, M) TK-3206(M) ) 470 to 512MHz (TK-3202(K2, M2) )
400 to 430MHz (TK-3206(M3) )
Measuring Range
10mV to 10V DC
Input Impedance
High input impedance for minimum circuit loading.
DC through 30MHz.
Frequency Range
10Hz to 1000MHz.
Frequency Stability
0.2ppm or less.
5A.
Frequency Range
50Hz to 10kHz.
Voltage Range
1mV to 10V.
Frequency Range
50Hz to 5kHz or more.
Output
0 to 1V.
Capability
3% or less at 1kHz.
Input Level
50mV to 10Vrms.
Measuring Range
DC to 1GHz or more
Center frequency
50kHz to 600MHz
Output Voltage
100mV or more
Approx. 8Ω, 3W.
5V to 10V, approx. 3A
+ Terminal (Red)
– Terminal (Black)
Major Specifications
Useful if ammeter equipped.
Connect the power cable properly between the battery jig
installed in the transceiver and the power supply, and be sure
output voltage and the power supply polarity prior to switching
the power supply ON, otherwise over voltage and reverse
connection may damage the transceiver, or the power supply
or both.
Note: When using the battery jig, you must measure the
voltage at the terminals of the battery jig. Otherwise, a slight
voltage drop may occur within the power cable, between the
power supply and the battery jig, especially while the
transceiver transmits.
SCHEMATIC DIAGRAM
S
+
+ Terminal
– Terminal
(Red)
(Black)
Power cable
Power
supply

Hide quick links: