Configuration Problems; Software Upgrade Failure; Hardware Failures - HP 6125XLG Installation Manual

Hp 6125xlg blade switch installation guide
Table of Contents

Advertisement

Parity—none
Stop bits—1
Flow control—none
Emulation—VT100
When you modify the settings for the console port of the switch, configure the same settings for the
console terminal.

Configuration problems

At the CLI, you can use related commands to display the blade switch information and locate the failures.
When you detect configuration errors, re-configure the blade switch or restore the factory settings for the
blade switch.
For more information about commands and configurations, see HP 6125XLG Blade Switch Configuration
Guides and HP 6125XLG Blade Switch Command References.

Software upgrade failure

HP recommends that you keep your software up-to-date. Periodically check the product webpage for
available updates.
To locate the software upgrade failure, verify that:
1.
Physical ports are correctly connected.
2.
All terminal parameters are correctly set when you log in to the blade switch through console port.
3.
The information on the HyperTerminal is correctly input, including that:
The baud rate set on the HyperTerminal and Console port are the same when software is
downloaded using XMODEM.
IP address, file name, and the assigned working directory of the TFTP server are correct when
software is upgraded using TFTP.
Verify that IP address, file name and the assigned working directory of the FTP server, FTP
username and password are correct when software is upgraded using FTP.
4.
The FTP server or the TFTP server is operating properly and correctly configured.
5.
The Flash has enough space to save the file to be downloaded.
6.
The file for upgrade is suitable for the product and the file type is correct.
7.
The system software image file and the BootWare file versions are correct. For the software version
matrix, see relevant Release Notes.

Hardware failures

When your blade switch is operating properly, the Health LED is green. If the LED is in other state, failures
have occurred.
To troubleshoot the failures:
1.
Verify that the enclosure is operating correctly.
2.
Verify that the blade switch is correctly installed. If not, pull out the blade switch and install it again.
16

Advertisement