Straight-Through Twisted-Pair Cable for
10 Mbps or 100 Mbps Network Connections
Because of the HP Auto-MDIX operation of the 10/100 ports on the switch, for all network
connections, to PCs, servers or other end nodes, or to hubs or other switches, you can use
straight-through cables.
If any of these ports are given a fixed configuration, for example 100 Mbps/Full Duplex, the
ports operate as MDI-X ports, and straight-through cables must be then used for connections
to PC NICs and other MDI ports.

Cable Diagram

N o t e
Pins 1 and 2 on connector "A" must be wired as a twisted pair to pins 1 and 2 on connector "B".
Pins 3 and 6 on connector "A" must be wired as a twisted pair to pins 3 and 6 on connector "B".
Pins 4, 5, 7, and 8 are not used in this application, although they may be wired in the cable.
.

Pin Assignments

Switch End (MDI-X)
Signal
receive +
receive -
transmit +
transmit -
Pins
1
2
3
6
Computer, Transceiver, or
Other End
Pins
Signal
1
transmit +
2
transmit -
3
receive +
6
receive -