Control gear and accessories
Electronic Ballasts
A range of GE electronic ballasts have been introduced to complement the 20, 35, 70 and 150W ConstantColor™
Ceramic Metal Halide lamps
Power controlled electronic ballasts suitable for operation of Ceramic Metal Halide lamps are available from various gear
manufacturers.
Advantages are:
• Good regulation against supply voltage variation
• Improved lamp colour consistency
• Elimination of lamp flicker
• Reduced weight of control gear
• Reduced electrical power losses
• Ballast noise reduced/eliminated
• Single piece compact unit
• Reduced wiring complexity in the luminaire
Features
• Integral version with open terminals for embodiment into luminaire
• Remote version with terminal cover and cable strain relief for location outside the luminaire
• 50,000 hours service life under the specified conditions
• Reduced power consumption compared to electromagnetic circuits
• Reduced component count and simplified wiring compared to electromagnetic circuits
• Rapid and controlled power run-up
• Lamp life maximised by square-wave current and constant lamp power
• Excellent lamp colour stability throughout life
• Automatic lamp failure shut-down
• Timed restart after mains voltage interruption
• Immune to mains voltage variations
General Information
Watts
Volts
Description
20
220-240
BLS/E/20W/CMHSMP
20
220-240
BLS/E/20W/CMH
20
220-240
BLS/E/20W/CMH/R
35
220-240
BLS/E/35W/CMH
35
220-240
BLS/E/35W/CMH/R
70
220-240
BLS/E/70W/CMH
70
220-240
BLS/E/70W/CMH/R
150
BLS/E/150W/CMH
220-240
150
BLS/E/150W/CMH/R
220-240
System Performance
System Power
W
System
lm/W
Lumens*
lm
Lamp Power
W
Lamp Efficacy
lm/W
Lamp Voltage Range
V
* Data shown relates to 3000K products. Please see lamp data sheets for performance of equivalent 4200K rated products.
12
Mounting
Weight
Pack Qty
Integral
110 g
12
Integral
190 g
12
Remote
230 g
12
Integral
215 g
12
Remote
230 g
12
Integral
300 g
12
Remote
310 g
12
Integral
430 g
12
Remote
445 g
12
20W
35W
70W
23.5
43
78
72
79
79
1700
3400
6200
20
39
72
85
87
86
70...125
70...125
70...125
Operating Characteristics
Mains Voltage
Mains Current
Mains Frequency
Power Factor
Allowed Mains Voltage Range
Ignition Voltage*
Lamp Operating Frequency
Max Cable Capacitance
Max Lamp Distance**
Ambient Temperature Range
Maximum Case Temperature
Thermal Cut-off on PCB
* If a hot lamp or no lamp is detected the ballast will attempt to start the lamp after one minute, if not successful further attempts are made up to a maximum
of 4 times in 5 minute cycles, then if not successful the ballast will shut-down. The ballast is reset automatically by a supply interruption.
** Typical value if cable capacitance is below the specifi ed limit
BLS/E/20W/
CMHSMP
A
Product Code
42387
13032
13034
13035
13036
13040
Circuitry
13047
13050
Wire cross section: 0.75...2.5 mm
13053
150W
BLS/E/20W/CMH
159
BLS/E/35W/CMH
88
14000
146
96
70...125
20W
20W
V
220...240
220...240
A
0.19
0.10
Hz
50
50...60
> 0.55
> 0.95
V
198...264
198...264
kV
< 3.5
< 2.5
Hz
133
150
pF
1000
1000
m
2
10
°C
-20...+50
-20...+50
°C
80
75
°C
110
110
Dimension
BLS/E/20W/CMH
BLS/E/70W/CMH
BLS/E/20W/CMH/R
BLS/E/35W/CMH
BLS/E/35W/CMH/R
BLS/E/70W/CMH/R
101,5
126
126
112,5
120
120
98
4,2
123
137
177
A
B
C
B
C
D
2
BLS/E/20W/CMH/R
L
N
BLS/E/35W/CMH/R
N
L
BLS/E/70W/CMH
BLS/E/70W/CMH/R
BLS/E/150W/CMH
BLS/E/150W/CMH/R
35W
70W
150W
220...240
220...240
220...240
0.18
0.33
0.69
50...60
50...60
50...60
> 0.95
> 0.95
> 0.95
198...264
198...264
198...264
< 2.5
< 2.5
< 2.5
150
150
150
3000
3000
3000
25
25
25
-20...+50
-20...+50
-20...+50
75
75
80
110
110
110
BLS/E/150W/CMH
BLS/E/150W/CMH/R
121
126
130
130
142,5
172
D
E
E
F
The ballasts comply with the relevant
parts of the following standards:
– RFI suppression EN 55015
– Harmonics EN 61000-3-2
– Immunity EN 61547
– Safety EN 60926/EN 60928/EN 61347
– Performance EN 60927/EN 60929
13
Need help?
Do you have a question about the ConstantColor CMH G8.5 and is the answer not in the manual?