Drive Enclosures - HP EVA P6000 Specification

Hp eva p6000 storage
Hide thumbs Also See for EVA P6000:

Advertisement

QuickSpecs
Configuration Information and Configuration Rules
EVA P6550 Dual
Controller Array,
Fibre Channel
and 1GbE
for Storage Centric Rack
EVA P6550 Dual
Controller Array,
Fibre Channel
and 10GbE (iSCSI/FCoE)
Array
for Storage Centric Rack

Drive Enclosures

Drive enclosures can be ordered separately to be installed in the field or they can be factory configured in racks. At least one drive
enclosure is required with each EVA P6300/P6350 Dual Controller and at least two drive enclosures are required with each EVA
P6500/P6550 Dual Controller for factory configuration. Drive enclosures can be ordered for factory configuration without controllers
for expansion beyond one cabinet. See below for more on expansion options.
NOTE: The following enclosures can only be ordered with #0D1 to be mounted in a cabinet in the factory.
M6612 3.5-inch SAS Drive
Enclosure
interconnect cables, and XCS firmware license. Order one unit for each EVA P6550 array
configuration.
NOTE: The Storage Centric rack configuration, for CTO only, will result in the controller
assembly being placed in the middle of the rack cabinet to allow for easy expansion of
the EVA P6550 in the future. The MPX200 Multi Function router, and X series servers
used as EVA Management Servers can be added. Other non-EVA components are not
permitted in CTO orders, but can be added in the field.
HP EVA P6550 Dual Controller Fibre Channel and 1GbE Array for Storage Centric Rack
One 2U Controller Enclosure with a 667MHz ABM, with two HSV360 controller modules,
each with 8GB of cache and each with two 8Gb/s FC host ports and four 1GbE (1Gb/s
iSCSI) ports. Also included with each controller enclosure are four 8Gb/s SFPs, mounting
hardware, power cords, SAS interconnect cables, and XCS firmware license. Order one
unit for each EVA P6550 array configuration.
NOTE: The Storage Centric rack configuration, for CTO only, will result in the controller
assembly being placed in the middle of the rack cabinet to allow for easy expansion of
the EVA P6550 in the future. The MPX200 Multi Function router, and X series servers
used as EVA Management Servers can be added. Other non-EVA components are not
permitted in CTO orders, but can be added in the field.
HP EVA P6550 Dual Controller Fibre Channel and 10GbE Array for Storage Centric
Rack
One 2U Controller Enclosure with a 667MHz ABM, with two HSV360 controller modules,
each with 8GB of cache and each with two 8Gb/s FC host ports and two 10GbE (10Gb/s
iSCSI/FCoE) ports. Also included with each controller enclosure are four 8Gb/s SFPs,
mounting hardware, power cords, SAS interconnect cables, and XCS firmware license.
Order one unit for each EVA P6550 array configuration.
NOTE: The Storage Centric rack configuration, for CTO only, will result in the controller
assembly being placed in the middle of the rack cabinet to allow for easy expansion of
the EVA P6550 in the future. The MPX200 Multi Function router, and X series servers
used as EVA Management Servers can be added. Other non-EVA components are not
permitted in CTO orders, but can be added in the field.
HP M6612 3.5-inch SAS Drive Enclosure
Select M6612 3.5-inch SAS drive enclosures to expand EVA P6300/P6350
configurations up to ten enclosures or to expand an EVA P6500/P6550 configuration up
to twenty enclosures.
SFF and LFF drive enclosures can be mixed in an EVA P6000. When mixed, up to twenty
DA - 13904 Worldwide — Version 26 — September 30, 2013
HP EVA P6000 Storage
QK722A#0D1
QK723A#0D1
AJ832A
Page 33