GE Monogram
®
Dimensions and Installation Information (in inches)
Combination Installations
Consideration must be given to the electrical supply
locations when the cooktop is installed with other
products in the same cabinet. Always refer to each
product's installation instructions for clearances
and electrical requirements.
• Install these cooktops with any exhaust hood of the
same or greater width; 300 CFM or greater air flow.
• The cooktop may be installed with a 36" Monogram
downdraft vent.
Electrical Requirements
Product rating is 120/208V or 120/240V, 60Hz. For 240V,
connect to a 40-amp circuit; connect to a 30-amp circuit
for 208V operation. The cooktop must be connected to
a supply circuit of the proper voltage and frequency and
protected by a time-delay fuse or circuit breaker.
For answers to your Monogram,
GE
®
appliance questions, visit our website at
ge.com or call GE Answer Center
800.626.2000.
36" Ribbon Cooktop
GE Profile
or
®
™
service,
®
*3-1/4"
1-3/4"
Min.
19-1/8"
2-1/2"
Min.
to Front
Edge
* 3-1/4" deep at the front. 4-5/8" deep at the rear conduit location.
Allow 5" minimum clearance below the cooktop bottom to
combustible materials.
605Dia128
21-1/4" at
center
36"
2" Min.
to Side Walls
33-7/8"
16" Min
Junction
Box
Listed by
Underwriters
Laboratories
R
R
Specification Created 12/04