Control Panel Information For Ohv30 - Baldor OHV Series 3KW-9KW Operator's Manual

Ohv series 3kw-9kw
Table of Contents

Advertisement

A = NEMA 515R GFCI DUPLEX. This receptacle is a ground fault circuit interrupter duplex rated at
20 amps. This receptacle must be tested on a regular basis (monthly).
B = STANDARD DUPLEX RECEPTACLE. This is your standard household duplex receptacle, it is
rated for 120 VAC, 15 Amps. When using this receptacle you are utilizing the ground fault
protection provided by the GFCI receptacle.
C = ELAPSED TIME METER. This meter displays a continuous running total of the hours
accumulated on the unit.
D = CIRCUIT BREAKER. This circuit breaker provides overload protection for the generator set.
When tripped, the circuit breaker plunger will extend out approximately 3/8".
CONTROL PANEL
For OHV30
- 13 -