Removing The Overheat Thermostat; Removing The Heating Temperature Sensor (N.t.c.); Removing The D.h.w. Temperature Sensor (N.t.c.) - Ariston MicroCombi 23 MFFI Servicing Instructions

Type c boilers
Hide thumbs Also See for MicroCombi 23 MFFI:
Table of Contents

Advertisement

1.5.7 Removing the overheat thermostat

1. Disconnect
the
connections "J1" (F
IG
2. Then remove the thermostat from its mounting by
releasing the securing clip (F
F
. 1.49
IG
1.5.8 Removing the heating temperature sensor
(N.T.C.)
1. Pull off the electrical connector and unscrew the sensor
probe using a suitable spanner (F
overheat
thermostat
. 1.48);
. 1.49 /1.50).
IG
J1
F
. 1.48
IG
. 1.51).
IG
F
. 1.51
IG

1.5.9 Removing the D.H.W. temperature sensor (N.T.C.)

electrical
1. Pull off the electrical connector and unscrew the sensor
probe using a suitable spanner (F
F
. 1.50
IG
. 1.52).
IG
F
. 1.52
IG
15

Hide quick links:

Advertisement

Table of Contents
loading