16
en | Troubleshooting Guide
Inside of
–
EnviroDome bubble
If status reports Heater No Power, then:
is foggy
–
–
If O.K., then:
–
Low Voltage flashing
–
on monitor display
If O.K., then:
–
If O.K., then:
–
If O.K., then:
–
F.01U.216.346 | 1.0 | 2011.04
Check the status of the Heater Module (ON-66-ENTER).
Turn off the power to the AutoDome.
Check the FX103 fuse in the Power Supply Box for power (24 V) to the heater module.
Check all wiring and connector pins to the heater module.
If using a non-Bosch power supply, confirm that it meets the Bosch AutoDome power
ratings. See the AutoDome Datasheet for specifications.
Check the mains input line voltage.
Check that the maximum wire length from the power supply has not been exceeded.
See the VG5 AutoDome Installation Manual.
Measure the AC voltage input to the camera while power is applied to the camera. The
voltage must be ≥ 21 VAC to stop the message.
User Manual
AutoDome 100 Series Fixed Camera
Bosch Security Systems, Inc.