GE Zoneline AZ41E12EAC Dimensions And Installation Information

Deluxe series cooling and electric heat unit
Hide thumbs Also See for GE Zoneline AZ41E12EAC:

Advertisement

AZ41E12EAC
GE Zoneline
Deluxe Series Cooling and Electric Heat Unit
®
Dimensions and Installation Information (in inches)
Electrical Wiring
All wiring, including installation of receptacle, must
be made in accordance with local electrical codes
and regulations.
Note: Aluminum wiring may pose special problems –
consult a qualified electrician.
Grille Options
Stamped Aluminum Grille – RAG60
Exterior Architectural Louvers Durable Polycarbonate:
RAG61 (Beige)
RAG63 (Bittersweet)
RAG62 (Maple)
RAG67 (Extruded Aluminum)
Retrofit Kits:
RAK901L – Wall Case Insulation for use with heat pumps.
RAK40 – Deflector Kit to adapt chassis for use with
existing exterior architectural louvered grilles.
Ducted Applications
4100 and 6100 series can be used with ductwork to heat or cool more than one room. RAK6052
Duct Adaptor is applied to top of case over air discharge/RAK601 Duct Extension is applied
to right or left of adaptor. Locally fabricated ductwork may be added to extend to maximum
recommended distance of 15 feet.
Electrical Connection
230/208 volt units may be plugged into a receptacle. 265 volt units are provided with a junction box
and require direct connection. (NEC Requires 265V Direct Connection) See Architects and Engineers
Design Data Manual for electrical connection information including use of sub-base for direct
connected units. Installation must comply with local electrical codes and regulations.
Power Connection kits required on all Zoneline chassis.
For answers to your Monogram,
GE Profile
®
GE
®
appliance questions, visit our website at
ge.com or call GE Answer Center
®
800.626.2000.
Zoneline RAC Wall Installation
Wall Case Dimensions
RAB71 Wall Sleeve
Heavy-gauge galvanized steel, with insulation.
A – 42" , B – 13-3/4" , C – 16"
RAB77 Wall Sleeve
Molded SMC fiberglass-reinforced polyester
compound.
A – 42-1/8" , B– 13-7/8" , C – 16-1/4
or
service,
Inside
A
C
B
265 Volt Sub-Base Connected Units
Sub-Base
RAK204E15
RAK204E20
RAK204E30
SIDE
VIEW
Room
Cabinet
Maximum Cord Extension (in inches)
21
Wall Opening Dimensions
Add 1/4" to A and C dimensions for all cut-out size.
RAB71 16-1/4" Min. H x 42-1/4" Min. W
RAB71 available in 16" , 24" , 28" and 31" depths
RAB77 16-1/2" Min. H x 42-3/8" Min. W
Power
Electric
Electric
Connection Kit
Heater Watts
Heat Amps
RAK5172
2,550
RAK5202
3,450
RAK5302
5,000
Specification Created 11/09
RAB71A = 16
RAB77A = 16-1/4
Outside
58
Min. Circuit
Protection
(Amps)
10.3
15
13.7
20
19.6
30
390546

Advertisement

loading

Summary of Contents for GE GE Zoneline AZ41E12EAC

  • Page 1 Power Connection kits required on all Zoneline chassis. For answers to your Monogram, GE Profile ® ™ ® appliance questions, visit our website at ge.com or call GE Answer Center service, ® 800.626.2000. Zoneline RAC Wall Installation Wall Case Dimensions RAB71 Wall Sleeve Heavy-gauge galvanized steel, with insulation.