3-1. OPERATING RANGE
(1) POWER SUPPLY
Rated voltage
208/230 V
Indoor unit
(2) OPERATION
Mode
Condition
Standard temperature
Maximum temperature
Cooling
Minimum temperature
Maximum humidity
Standard temperature
Heating
Maximum temperature
Minimum temperature
3-2. OUTLET AIR SPEED AND COVERAGE RANGE
Model
Mode
MSZ-D30NA
HEAT
MSZ-D36NA
MSZ-D30NA
MSZ-D36NA
COOL
MSY-D30NA
MSY-D36NA
Min.187 V
1 phase
60 Hz
DB
80
90
67
70
80
70
Airlow
Function
(CFM)
Dry
848
Dry
848
Wet
763
Guaranteed Voltage
208 V
230 V Max.253 V
Intake air temperature (°F)
Indoor
WB
67
73
57
78 %
60
67
60
Air speed
Coverage
(ft./sec.)
range (ft.)
23.6
45.0
23.6
45.0
21.3
40.7
6 6
Outdoor
DB
95
115
14
47
75
14
The air coverage range is the figure up
to the position where the air speed is 1
ft./sec., when air is blown out horizon-
tally from the unit properly at the High
speed position.
The coverage range should be used
only as a general guideline since it var-
ies according to the size of the room
and furniture arranged inside the room.
WB
43
65
13