9.
Rotate baffle. Reinsert baffle into air chute (as shown)
so that baffle tabs fit all the way into slots in air chute.
An audible "click" wiII be heard when fully instalIed. This
wil! close off the air flow through the non-ducted slots on
top of hood.
10. Re-install air chute, re-connect wire harness, and
replace light panel.
NOTE: Be careful not to trap wires between support
fin
and light panel.
SLOTS
TABS
SUPPORT FiN
11. Remove appropriate
Duct Knockout sf_s} f rom top or back
of hood.
TOP RECTANGULAR
DUCT KNOCKOUT
(Remove for 3¼" x 10"
Vertical & for 7" Round
Discharge)
SEMI-CIRCULAR
DUCT KNOCKOUT
(Remove for 7" Round
Discharge)
REAR
RECTANGULAR
DUCT KNOCKOUT
(Remove for 3¼" x 10"
Horizontal Discharge)
12.31_ '' x 10" Ducted Discharge
OnBy:
Attach Damper/Duct
Connector
over knockout opening.
Make sure damper Pivot is nearest to Top/Back
Edg_ of
hood. Remove _
from damper flap.
13.7"
Round Ducted Discharge
Onmy:
Re-install 7" Round Duct PBate removed in Step #1 under
"PREPARE THE HOOD" section. Install a 7" round damper
(purchase
separately).
Damper flap must open freely in
direction of air flow (away from range hood).
UP TO 1"
SIDE-TO-SDE
ADJUSTMENT
TAPE
TOP/BACK
EDGE
To accomodate
off-center
ductwork,
the Damper/Duct
Connector
can be installed
up to 1-inch on either side of
hood center or the 7" Round Duct PBate can be installed up
to 1/2" on either side of hood center. In extreme off-center
installations,
one end of the duct connector
may need to
be trimmed
to cmearthe emectrica{ cabme c_amp.
PIVOT
,'Vertical d_scharge
uos_tlon ShOWn)

Advertisement