Component Specifications
To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing.
Illustration
Limit Thermostat
Sensor/Thermistor
Heater/Heating
Element
120v/60hz, 650 watts
± 5% in air, 830 watts
± 5% in 90°F water
Drain Motor
120v/60hz
45 watts
16026393
!
Component
Close on Temperature drop @ 149°F
± 7°F (Temp) .......................................
Open on Temperature drop @ 164°F
± 4°F (Temp) .......................................
10KΩ ± 3% at 77°F and 2.4 k Ω ±
6.5% at 140°F
J5 pin 1 - Orange (Temp) to J5 Pin 4 -
Red (Neutral) ......................................
Measure resistance from ST1
Red/Black (Heater) to ST11 White
(Common) ...........................................
Measure resistance from
ST6 Gray (Drain) to ST4 Black
(Common) ...........................................
See section "Motor Connections and
Diagram" for wiring contacts.
WARNING
Test Procedure
4
Results
0 Ω
= Closed
Infinite Ω = Open
Infinite Ω = Open
0 Ω
= Closed
16 Ω
(This value assumes the high limit
thermostat is closed).
25 Ω
©2005 Maytag Services
July 2005