Daikin FBQ60EVE4 Operation Manual

Daikin FBQ60EVE4 Operation Manual

Split system. ceiling-mounted duct type

Advertisement

SPLIT SYSTEM

MODELS
(Ceiling-mounted Duct type)
FBQ50EVE4
FBQ60EVE4
FBQ71EVE4
FBQ100EVE4
FBQ125EVE4
FBQ140EVE4

OPERATION MANUAL

Air Conditioner
English
Bahasa
Indonesia

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FBQ60EVE4 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Daikin FBQ60EVE4

  • Page 1: Operation Manual

    OPERATION MANUAL English SPLIT SYSTEM Air Conditioner Bahasa Indonesia MODELS (Ceiling-mounted Duct type) FBQ50EVE4 FBQ60EVE4 FBQ71EVE4 FBQ100EVE4 FBQ125EVE4 FBQ140EVE4...
  • Page 2: Table Of Contents

    the appliance. Cleaning and user Thank you for purchasing this product unit. Carefully read this operation manual to ensure maintenance shall only be done by proper operation. persons described in manual. After reading the manual, file it away for future reference.
  • Page 3 Start or stop the air conditioner with the Be aware that prolonged, direct exposure remote controller. Never use the power to cool or warm air from the air conditioner, circuit breaker for this purpose. or to air that is too cool or too warm can Otherwise, it may cause a fire or water leakage.
  • Page 4 Never touch the internal parts of the remote CAUTION controller. Touching certain internal parts will cause electric Children should be watched so that they do shocks and damage to the remote controller. not play with the indoor unit or its remote Consult your local dealer about checking and controller.
  • Page 5: What To Do Before Operation

    Do not install the air conditioner at any place NOTE where there is a danger of flammable gas leakage. • Contact your local dealer in case of changing the In the event of a gas leakage, build-up of gas combination or setting of group control and two near the air conditioner may result in a fire.
  • Page 6: Operation Range

    g. Where there are machines generating 3. OPERATION RANGE electromagnetic waves h. Filled with acid and/or alkaline steam or vapor If the temperature or the humidity is beyond the following conditions, safety devices may work and • Is a snow protection measure taken? the air conditioner may not operate, or sometimes, For details, consult your local dealer about snow water may drop from the indoor unit.
  • Page 7: Operation Characteristics

    • If the main power supply is turned off during DEFROST OPERATION operation, operation will restart automatically (Frost removal operation for the outdoor after the power turns back on again. unit) • As the frost on the coil of an outdoor unit Read the operation manual attached to the increase, heating effect decreases and the remote controller.
  • Page 8: Optimum Operation

    • If the PROGRAM DRY OPERATION is used • Use the TIMER OPERATION effectively. when the indoor temperature is low, frost forms It takes some time until the indoor temperature the heat exchanger of the indoor unit. In this case, reaches the set temperature.
  • Page 9 NOTE • The indication can be turned off while the unit is • You may change the time of indication “  either operating or stopped.  ” or “Time to clean filter”. HOW TO CLEAN AIR OUTLET, OUTSIDE If the indoor unit is used in a space where the PANELS AND REMOTE CONTROLLER air is too contaminated, ask your local dealer for solution.
  • Page 10: Not Malfunction Of The Air Conditioner

    HEATING OPERATION within 6 hours after the 9. NOT MALFUNCTION OF THE AIR power is supplied to the air conditioner. CONDITIONER • Some models perform the following operation to protect the devices. The following symptoms do not indicate air If the HEATING OPERATION is performed conditioner malfunction within 6 hours after the power is supplied to the • HEATING OPERATION within 6 hours after the...
  • Page 11 The above operation is performed not only It takes some time until the fan speed at the time of installation, but every time the changes. Raise the set temperature. After a power circuit breaker is turned off/on. while, the fan speed changes. For comfortable use, do not turn off the IV.
  • Page 12: Troubleshooting

    VI. DUST FROM THE INDOOR UNITS • Check if there is a power failure. • Dust may blow out from the unit after Wait until power is restored. If power failure oc- starting operation from long resting time. curs during operation, the air conditioner auto- Dust absorbed by the unit blows out.
  • Page 13: When The Air Conditioner Is Malfunctioning

    • Check if direct sunlight enters the room (when • If the display “     ”, “UNIT No.”, and cooling). the OPERATION lamp flash and the Use curtains or blinds. “MALFUNCTION CODE” appears. (In case of • When there are too many inhabitants in the BRC1C, BRC1D) room (when cooling).
  • Page 14 Gedung Wisma Keiai Lantai 18 dan 19, Jl. Jend. Sudirman Kav.3, Karet Tengsin, Tanah Abang, Jakarta Pusat, DKI Jakarta, 10220 Main Line (Hunting): +62-21 572 4377 Fax Line: +62-21 572 4366 http://www.daikin.co.id 3P338600-20K EM14A020A [1509] HT...