Daikin FTXD50BVMA Operation Manual page 10

Room air conditioner
Hide thumbs Also See for FTXD50BVMA:
Table of Contents

Advertisement

I To set the clock
1. Press "CLOCK button".
is displayed.
blinks.
2. Press "TIMER setting button"
to set the clock to the present
time.
Holding down "
idly increases or decreases the time dis-
play.
3. Press "CLOCK button".
blinks.
I Turn the breaker ON
• Turning ON the breaker opens the flap, then
closes it again. (This is a normal procedure.)
NOTE
I I I I Tips for saving energy
• Be careful not to cool (heat) the room too much.
Keeping the temperature setting at a moderate level helps save energy.
• Cover windows with a blind or a curtain.
Blocking sunlight and air from outdoors increases the cooling (heating) effect.
• Clogged air filters cause inefficient operation and waste energy. Clean them
once in about every two weeks.
I I I I Please note
• The air conditioner always consumes 15-35 watts of electricity even while it is not operating.
• If you are not going to use the air conditioner for a long period, for example in spring or autumn, turn the breaker OFF.
• Use the air conditioner in the following conditions.
Mode
Operating conditions
COOL
Outdoor temperature:〈3/4MK〉 10 to 46 °C
Indoor temperature: 18 to 32 °C
Indoor humidity: 80% max.
HEAT
Outdoor temperature:〈3/4MX〉 –15 to 21 °C
Indoor temperature: 10 to 30 °C
DRY
Outdoor temperature:〈3/4MK〉 10 to 46 °C
Indoor temperature: 18 to 32 °C
Indoor humidity: 80% max.
• Operation outside this humidity or temperature range may cause a safety device to disable the system.
" or "
" button rap-
〈3/4MX〉 –10 to 46 °C
〈RK(X)〉 –5 to 46 °C
〈RX〉 –15 to 24 °C
〈3/4MX〉 –10 to 46 °C
〈RK(X)〉 –5 to 46 °C
C
HOME LEAVE
ON/OFF
TEMP
POWERFUL
MODE
FAN
SILENT
SENSOR
SWING
ON
CANCEL
OFF
TIMER
Recommended temperature setting
For cooling:26°C – 28° ° ° ° C
For heating:20°C – 24°C
If operation is continued out of this range
A safety device may work to stop the operation.
(In multi system, it may work to stop the operation of the out-
door unit only.)
Condensation may occur on the indoor unit and drip.
A safety device may work to stop the operation.
A safety device may work to stop the operation.
Condensation may occur on the indoor unit and drip.
2
1.3
9

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FTXD50BVMA and is the answer not in the manual?

Questions and answers

Terry
April 10, 2025

On light comes on wall unit that’s all New batteries in remote Same with both remotes as we have two

1 comments:
Mr. Anderson
April 10, 2025

The light on the Daikin FTXD50BVMA wall unit may be on even with new batteries in both remotes due to a malfunction in the indoor/outdoor unit communication or a PCB issue. Possible causes include:

- Wrong models interconnected (indoor and outdoor units not compatible)
- Defective indoor or outdoor unit PCB
- Incorrect PCB mounted in the indoor or outdoor unit
- Signal blockage between remote and indoor unit

Check if the remote is aimed directly at the unit with no obstructions. If the issue persists, further diagnosis of unit wiring or PCB may be needed.

This answer is automatically generated