7 AC Power Draw and
Thermal Dissipation
(continued)
AC Power Draw and Thermal Dissipation:
Pink noise 12dB crest factor, bandwidth limited 22Hz to 22kHz.
Typical line impedance used.
Measurements made with 120VAC mains. Line current figures for 230VAC units derived by multiplying 120VAC figures by 0.5.
Data based on all channels driven.
At Idle (8.4 Ohm mode )
At Idle (70/100V mode)
1/8th Power Pink Noise
Typical of program material
just at clip.
1/3rd Power Pink Noise
Typical of program material
with severe clipping.
page 32
The CobraNet and Control Module is not included.
Rated
Line Current
Load
Power
8 Ohms/Ch.
160x8
16 Ohms Bridge
320x4
4 Ohms/Ch.
200x8
8 Ohms Bridge
400x4
70V/Ch.
200x8
100V Bridge
200x4
8 Ohms/Ch.
160x8
16 Ohms Bridge
320x4
4 Ohms/Ch.
200x8
8 Ohms Bridge
400x4
70V/Ch.
200x8
100V Bridge
200x4
CTs 8200USP/CN
Line Current
120VAC
230VAC
watts in
70
114
8.7
4.3
725
13.3
6.7
1155
10.1
5.1
857
13.1
6.5
1136
19.3
9.7
1748
15.3
7.7
1344
CTs Multi-Channel Power Amplifi ers
Watts
Thermal Dissipation
dissipated
watts out
Btu/hr
0
70
239
0
114
389
172
553
1889
218
938
3200
203
653
2230
437
699
2385
557
1190
4062
552
792
2702
Operation Manual
kcal/hr
60
98
476
807
562
601
1024
681

Advertisement