ELECTRICAL
INSTALLATION
INSTRUCTIONS:
WARNING:
DISCONNECT
ELECTRICAL
POWER
SUPPLY
Al
;E FUSE/
CIRCUIT
BREAKER
BOX BEFORE
MAKING
ELECTRICAL
0.3,
:ECTIONS.
Follow
the National
Electrical
Code and/or
your
local electrical code in all details.
In older houses with limited
circuits, or if it appears the circuit is heavily
loaded,
run 3 line directly
to the maul fuse box.
Models KWD-200. and
KWS-200
- 115 Volt, 60 Hertz.
1. Remove the electric31 access cover on the bearing bracket assembly.
2. Pull out the two le3ds provided.
3
Instill
st3nd3rd strain relief connector
(not furnished) into the threaded opening
in bs3ring bracket assembly.
4. Insert
electrrcal
power
supply
line
into
connector.
Tighten
connector.
5. Connect
electric31 power supply
line to the two leads provided.
Connect to
ground (See Fig. 3 and grounding
instructions
below).
Press wires into electrical
access compartment
and replace cover.
hiodels KWE-100, and KWI-100 - 115 Volt, 60 Hertz
Sreps 1, 7, and 3 3re the s3me as lllodels KWD-200, and KWS-200.
4. Install the operating control switch where it is easily accessible. Recommended:
On-Off switch suitable for operation of l/2 H.P. motor (Switch not furnished).
5. Run Hexible
conduit,
or equivalent,
from the control
switch to the disposer
motor leads located in the bearing bracket assembly. Insulate connections
and
connect
unit
ta ground.
(See Fig. 3 and grounding
instructions
below.)
6. Run power
supply,
in accordance
with local codes, from control
switch
to
electric31 serviie panel.
7. Press \vrres into the electrical access compartment
and replace cover.
IUOTE: hlod~ls KWE-300,
and KU'I-200
are equipped
with a manual reset (RED
SUTTOS)
motor overload protector.
hlodels KWD-200, and KWS-200 are equipped
wirh an 3utomatic
reset motor
overload
protector.
In case of overload
'Trip",
a
minimum
of three to live minutes cooling time must be allowed before resetting.
Ii disposer has been running
for more than IO-15 minutes (a "well heated"
con-
ditlon).
reset time may be 20-25 minutes.
GROUNDING
INSTRUCTIONS
This appliance
must be connected
to a
grounded
metal,
permanent
wiring
sys-
tem;
or
an equipment-grounding
con-
ductor
must
be run
with
the circuit
conductors
and connected
to the equip-
ment-grounding
terminal
or lead on the
3ppli3nce.
KITCHENAID
FORM
14610
(5 831
=-/I
-/
7P?
d
Fig. 3
PRINTED
IN U.S.A.