U.S. Range Broiler Installation And Operation Manual

Cuisine infra-red broiler

Advertisement

Quick Links

INSTALLATION AND
OPERATION MANUAL
INFRA-RED BROILER
FOR YOUR SAFETY:
DO NOT STORE OR USE GASOLINE
OR OTHER FLAMMABLE VAPORS OR
LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER
IMPROPER INSTALLATION, ADJUSTMENT,
ALTERATION, SERVICE OR MAINTENANCE
CAN CAUSE PROPERTY DAMAGE, INJURY,
OR DEATH. READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR
SERVICING THIS EQUIPMENT
Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent
using genuine Garland replacement parts. Garland will have no obligation with respect to any product that has been
improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation
instructions provided with the product, or any product that has its serial number defaced, obliterated or removed,
or which has been modified or repaired using unauthorized parts or by unauthorized service agents.
For a list of authorized service agents, please refer to the Garland web site at http://www.garland-group.com.
The information contained herein, (including design and parts specifications), may be superseded and is subject
to change without notice.
GARLAND COMMERCIAL INDUSTRIES
185 East South Street
Freeland, Pennsylvania 18224
Phone: (570) 636-1000
Fax: (570) 636-3903
Part # 4517385 (02/20/08)
Part # 4517385 (02/20/08)
CUISINE
APPLIANCE
WARNING:
GARLAND COMMERCIAL RANGES, LTD.
1177 Kamato Road, Mississauga, Ontario L4W 1X4
CANADA
Phone: 905-624-0260
Fax: 905-624-5669
PLEASE READ ALL SECTIONS OF THIS MANUAL
AND RETAIN FOR FUTURE REFERENCE.
THIS PRODUCT HAS BEEN CERTIFIED AS
COMMERCIAL COOKING EQUIPMENT AND
MUST BE INSTALLED BY PROFESSIONAL
PERSONNEL AS SPECIFIED.
IN THE COMMONWEALTH OF MASSACHUSETTS
THIS PRODUCT MUST BE INSTALLED BY A
LICENSED PLUMBER OR GAS FITTER. APPROVAL
NUMBER: G-1-07-05-28
For Your Safety:
Post in a prominent location, instructions to be
followed in the event the user smells gas. This
information shall be obtained by consulting
your local gas supplier.
Enodis UK LTD.
Swallowfi eld Way, Hayes, Middlesex UB3 1DQ ENGLAND
Telephone: 081-561-0433
Fax: 081-848-0041
© 2006 Garland Commercial Industries, Inc.
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for U.S. Range Broiler

  • Page 1 Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent using genuine Garland replacement parts. Garland will have no obligation with respect to any product that has been improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation instructions provided with the product, or any product that has its serial number defaced, obliterated or removed, or which has been modified or repaired using unauthorized parts or by unauthorized service agents.
  • Page 2: Important Information

    IMPORTANT INFORMATION WARNING: This product contains chemicals known to the state of California to cause cancer and/or birth defects or other reproductive harm. Installation and servicing of this product could expose you to airborne particles of glass wool/ceramic fibers. Inhalation of airborne particles of glass wool/ceramic fibers is known to the state of California to cause cancer.
  • Page 3: Table Of Contents

    Broiler Section ........
  • Page 4: Technical Specifications

    Input BTU/Hr Orifice Per Section Size DMS 70,000 # 56 ELECTRICAL SUPPLY* Propane 10” WC 120V 60Hz, 1Amp MODEL DESIGNATIONS Model Number Broiler Burner C2100MX Infra-Red CLEARANCES Combustible Noncombustible Construction Construction Rear 6” (152mm) 6” (152mm) 6” (152mm) 32-3/4" [832mm]...
  • Page 5: Introduction

    Where the range is to be mounted on a dais or cove base, it is shipped without legs. Legs must be fitted to the oven where it is installed on a combustible floor. 4. The type of gas and supply pressure that the equipment was set-up for at the factory is noted on the data plate and on the packaging.
  • Page 6: Appliances Equipped With Casters

    INSTALLATION continued B. If it is a new installation have the gas authorities check the meter size and piping to assure that the unit is supplied with the necessary amount of gas pressure required for operation. C. If it is additional or replacement equipment have the gas authorities check the pressure to make certain that existing meter and piping will supply fuel to the unit with not more than 1/2”...
  • Page 7: Electrical Connection

    (including fasteners), should be stored safely for re-installation. 1. Be sure that all valves are in the “OFF” position. 2. Turn on the main gas supply valve. Light all broiler pilots. OPERATION Infra-Red Burners The GARLAND® Infra-Red Broiler is a direct radiant heavy duty gas broiler utilizing four (4) extremely efficient gas burners in each broiling section.
  • Page 8: Product Application Information

    The broiler rack can be easily raised or lowered to provide for the desired distance of the product from the heat source and is readily pulled out for ease of loading and unloading.
  • Page 9: Care & Cleaning

    The filter can be cleaned by hand with dish detergent or run though the dishwasher. Remove, empty and wash the broiler grease drawer or container at least once a day. Well Done Minutes...
  • Page 10: Instructions For Removal Of Grid Rack & Grid Rack Frame

    Remove the broiler grid racks as follows: 1. Bring the grid rack down to the lowest adjustment position. 2. Pull the entire grid rack out of the broiler as far as possible. 3. Remove grid rack grease drip chute (located below wire rack) by grasping hold of the chute and pulling forward out of the frame guides.
  • Page 11 Part # 4517385 (02/20/08) Page 11...
  • Page 14 Page service. professionnel nettoyés être doivent infrarouge températures résistant toxique lubrifi sans végétale l’huile doivent secs, être semblent roulements rouleaux. à roulements propres, maintenus être doivent chariot périodiquement retirer à brûleurs l’avant élevées. partie roulements pour avec és lubrifi être supérieure lavés été...
  • Page 15 (02/20/08) 4517385 n° Pièce sécurité. raisons position dans crémaillère levage l’appareil. séparé maintenant chariot. sortir crémaillère chariot rails encoches roulements jusqu’à l’avant Continuer chariot. l’ensemble butées à manière l’avant cadre tirer poignée l’ensemble l’avant touchent butées possible loin aussi vide cadre crémaillère.
  • Page 16 Page cuisson avant etc. 4-1/2 — — 4-1/2 2-1/2 3-1/2 6-1/2 5-1/2 5-1/2 5-1/2 Minutes Minutes Cuit Bien point MINUTES grille. position temps, auront infrarouges expérience l’utilisateur technique indicatif titre à donnés sont suivants indiqués temps fait nouveau grille. à coller produits d‘empêcher...
  • Page 17 à brûleurs rôtissoire. pour rendement haut à à brûleurs intensif l’usage à destinée directe radiante GARLAND infrarouge Infrarouge FONCTIONNEMENT Page bouclier amme commande. d’y possible robinets veilleuse l’aide À Ouvrir Brancher Utilisation brûleur. céramique treillis céramique.
  • Page 18 Page nouveau. essayer minutes robinet fermer robinet, l’ouverture délai dans ferait l’allumage ouvert. robinet dont brûleurs vérifi l’utilisateur responsabilité sera L’alimentation section cette veilleuses section brûleurs alimentera nécessaire. moment és vérifi être doivent veilleuses Cependant, usine. réglés testés four. nouveau. vérifi Réparer ci-dessus.
  • Page 19 (02/20/08) 4517385 n° Pièce diamètre être doit appareils canalisation nécessaire. débit s’assurer sante suffi disponibilité établir à façon l’installation moment locale l’avant. à d’air l’appareil, devant encombrants devra fonctionner besoin veilleuses évacué. d’air quantité pièce dans entrant d’air quantité remplacement l’air nécessaire fonctionne...
  • Page 20 Page vérifi connexion, à montage L’installation (152mm) (152mm) (152mm) Combustible Combustible Construction Construction réparations pour sant suffi Exigences « édition), dernière norme pour sécurité Normes « édition) C22.1- l’électricité, canadien Code conforme être doit électrique connexion échéant. CSA-149.1 conforme être doit cace.
  • Page 21 (02/20/08) 4517385 n° Pièce ENTRÉE [864mm] [102mm] 4" [146mm] 5-3/4" ÉLECTRIQUE PRISE [1756mm] 69-1/8" INSTALLÉ] [CUTOMER DÉVIATEUR FUMÉE [832mm] 32-3/4" [159mm] 6-1/4" (152mm) (152mm) (152mm) Combustible Combustible Construction Construction DÉGAGEMENT Infrarouge Rôtissoire Brûleur Modèle MODÈLES DÉSIGNATIONS manuel. dans également troure 60Hz, 120V ÉLECTRIQUE...
  • Page 22 Page ........
  • Page 23 (02/20/08) 4517385 n° Pièce combustibles l’appareil congénitales malformations carbone monoxyde L’inhalation vous peut produit L’utilisation céramiques fibres verre laine poussières reproduction. problèmes causant comme Californie produits stocker abords causer pouvant comme réglage. mauvais cancer. causant comme laine particules exposer vous peut produit d’autres...
  • Page 24 Page Inc. Industries, Commercial Garland 081-848-0041 Télécopieur 081-561-0433 Téléphone ANGLETERRE Middlesex Hayes, Way, Swallowfi LTD. Enodis préavis. compris document présent site consulter autorisés, service autorisées pièces avec réparé dont produit quel n’importe conformément entretenu été obligation aucune n’aura Garland agent ectués...

This manual is also suitable for:

C2100mx

Table of Contents