3-5 EDID Installation with Windows Program

- After Replacing the Main Board
-EDID Installation (Analog and Digital)
-Factory Reset(Using Power key)
During Power off, press Power key for 5 seconds.
With 1 beep sound, Factory Reset executes.
1. Execute "WinDDC.exe"
2. Click "Sys Config"±
Select "Station : Write station".
Check "Serial No and Week : Don't change"±
Click "Save"±
3. Click "Open" icon.
Select "Connected Port #1" and Next "OK".
* File Name - 305T.DDC
Press enter key on your keyboard.
4. Confirm the "DDC OK".