Download Print this page

HP ProLiant DL585 Generation 2 Specification page 9

Hide thumbs Also See for ProLiant DL585 Generation 2:

Advertisement

QuickSpecs
Standard Features
Availability
Serviceability
Security
Power Supply
UPS and PDU Power
Cord Matrix
Server Power Cords
Smart Array P400 Controller with standard Battery Backed Write Cache (BBWC) Enabler
provides transportable data protection and increases overall controller performance. Up to
512MB Battery Backed Write Cache protection available on all HP ProLiant DL585 G2
models.
Up to eight hot-plug SFF SAS Hard Drives
Dual Hot-Plug Redundant Power Supplies
Hot-Plug Redundant Fans (standard)
Fans are N+1 hot plug redundant and individually removable.
System Insight Display - precisely depicts all major subsystems of the server (PCI I/O,
Memory, CPU, Redundant Cooling, Interlock, Thermtrip) and gives instant visual indication
of fault status. Located on top front of server, beneath lid.
Tool-less, virtually cable-less interior design
Tool-less access to interior of server
Two ejectable, slimline Media Bay media drives (DVD/CD-RW standard with support
for optional floppy or optical drives) are removable without the use of tools
Front accessible processors and memory
PCI Card Guides locks full length PCI cards in place during transit
Six individually removable fans connect without cables to the system board
Tool-less removal of system board
Quick Deploy Rails
Tool-less design "snap in" rail
Power-on password
Keyboard password
Diskette drive control enable/disable
Diskette boot control enable/disable
External USB port enable/disable
Network Server Mode
Serial interface control
Administrator's password
Removable Diskette drive (optional)
Removable optical drive
910W (low line), 1300W (high line) with 12V main output. Size is 2.8"(H) X 4.9"(W) X 7.5"(L).
NOTE: One Hot Plug Power Supply ships standard with 2.0GHz and 2.2GHz models (optional
Redundant Hot Plug Power Supply Option Kit).
NOTE: Two Hot Plug Power Supplies ship standard with 2.4GHz, 2.6GHz, 2.8GHz, and 3.0GHz
models.
Please see the UPS and PDU cable matrix that lists cable descriptions, requirements, and
specifications for UPS and PDU units:
http://h18004.www1.hp.com/products/servers/proliantstorage/power-protection/index.html.
IEC320-C14 to IEC320-C19 Jumper Cord
NOTE: The HP ProLiant DL585 G2 servers ship standard with a 6-foot IEC 320-C14 to IEC320-
C19 jumper cord.
DA - 12575 U.S. QuickSpecs — Version 28 — 11/27/2007