American Dryer Non-Tilting Phase 5 ML-200 Installation & Operator's Manual page 22

American dryer corporation ml-200 non-tilting phase 5 installation/operator's manual

Advertisement

7.5 Hp Blower/3 Hp Drive M otor
E
LECTRIC
IMPORTANT:
208 VAC and 230 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTES: A. Fuse ratings are dual element-time delay-current limiting, class RK1 or RK5 ONLY.
B. Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct breaker
size according to appliance amp draw rating and type of breaker used.
C. Circuit breakers for 3
SERVICE
PHASE
VOLTAGE
208
230
380
416
460
* AWG Stranded Type Wire...for individual lengths less than 100 feet (30.48 meters).
M LG-200 (Gas)
S
S
ERVICE
PECIFICATION
dryers must be 3-pole type.
Ø
APPROX.
WIRE
AMP DRAW
SERVICE
60 Hz
3/4
37
3
36
3/4
---
3/4
---
3/4
18
(
PER DRYER
MINIMUM
WIRE
SIZE*
50 Hz
---
4
---
4
20
8
19
8
---
8
18
)
FUSING
CIRCUIT
Dual Element
BREAKER
Time Delay
60
80
60
80
30
40
30
40
30
40