FOR YOUR SAFETY READ BEFORE LIGHTING /
WARNING
If you do not follow these instructions exactly, a fire or explosion may
result causing property damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by hand. When lighting the pilot,
follow these instructions exactly.
B.
BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell
next to the floor because some gas is heavier than air and will settle on the floor.
WltAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob. Never use tools. If the
knob will not push in or turn by hand, don't try to repair it, call a qualified service
technician or gas supplier. Force or attempted repair may result in a fire or
explosion.
D. Do not use this appliance if any part has been under water. Immediately call a
qualified service technician to inspect the appliance and to replace any part of the
control system and any gas control which has been under water.
LIGHTING
INSTRUCTIONS
WARNING
• If fireplace
has glass doors, never operate this heater with glass doors
closed. If you operate heater with doors closed, heat buildup inside
fireplace will cause glass to burst. Also if fireplace opening has vents at
the bottom, you must open the vents before operating heater.
• You must operate this heater with a fireplace screen in place. Make sure
fireplace
screen is closed before running heater.
NOTICE
During initial operation of new heater, burning logs will give off a paper-
burning smell. Orange flame will also be present. Open damper or
window to vent smell. This will only last a few hours.
Note: Homeowners
generally prefer to operate their heater with the chimney damper
closed. This will put all the heat into the room. However there may be times you will
desire the full flames of the Hi heat setting but will find the heat output excessive. You
can open the chimney damper (if you have one) fully or partially to release some of
the heat. WARNING: Damper handle will be hot if heater has been running.
l. STOP! Read the safety information above.
2. Make sure manual shutoff valve is fully open.
3. Press in and turn control knob clockwise _
to the OFF position.
Figure 20. Control Knob and Ignitor Button Location
4. Wait five (5) minutesto clear out any gas. Then smell for gas, including near the
floor. If you smell gas,STOP! Follow "B" in the safety information above. If you
don't smell gas,go to the next step.