Diagnostic Flow Charts; Tech Tips - Whirlpool 8177893 Manual

Direct spark ignition system
Table of Contents

Advertisement

SECTION 5
SECTION 5
SECTION 5
SECTION 5
SECTION 5

TECH TIPS

COOKTOP

DIAGNOSTIC FLOW CHARTS

Start
Does cooktop
spark properly?
no
Check the high voltage igniter wires for
continuity and proper connections from DSI
control to igniters. Make sure the burner
caps are the correct size and are properly
oriented. Also, if the supply voltage is
less than 102 VAC, the spark might not occur.
Diagnose the main wiring
harness. 120 VAC should
always be present at this point.
Diagnose the cooktop wiring
harness. Check the cooktop
switches for the proper function.
NOTE: The range must be plugged in for
at least 40 seconds before this test can begin.
yes
Done
no
no
Replace the DSI control.
- 23 -
Is 120 VAC
present from J1-4
to J1-10?
yes
With the cooktop
knob in LITE, is
120 VAC present
from J1-4 to J1-9?
yes

Advertisement

Table of Contents
loading

Table of Contents