3M Touch Screen Controller SX112 Reference Manual page 33

Formerly ex ii 3700sp
Table of Contents

Advertisement

3M™ MicroTouch™ Controller SX112 Reference Guide
±8 kV Contact Discharge
±22 kV Air Discharge
* ESD discharges to the tip and tapered end of the pen when connected to an SX112 controller
Operating and Storage Environmental Conditions
Operating Temperature Range
Operating Humidity Range
(All Humidity is Non-Condensing)
Storage Temperature Range
Storage Humidity Range
(All Humidity is Non-Condensing)
Agency Compliance
Reliability – Mean Time To Failure
Storage and Operating Temperature with Humidity Conditions
*
- 1 "touch" allowed
Compliant with Class 2 operation per section 9 of IEC 61000-4-2
*
– Normal Operation – No false touches
Compliant with Class 1 operation per section 9 of IEC 61000-4-2
UL Recognized Component (UL File No. E155649)
3M Touch Systems, Inc. Proprietary Information
- 15 °C to +70 °C
< 36° C 0-90% RH
≥ 36 °C see Figure below
- 30 °C to +70 °C
< 36°C 0-90% RH
≥ 36 °C see Figure below
4 Million Hours MTTF -
Calculated per Mil Handbook 217-F1 @ 35°C
33