  • Page 1 MicroTouch ™ ™ Controller RX142 Reference Guide Formerly SC400 Serial Resistive Read and understand all safety information contained in this document before using this product. 3M Touch Systems, Inc. Proprietary Information...
  • Page 2 3M Touch Systems, Inc. warranty, then 3M Touch Systems, Inc. sole obligation and User’s and Purchaser’s exclusive remedy, will be, at 3M Touch Systems, Inc. option, to repair or replace that Product quantity or software media or to refund its purchase price.
  • Page 3: Table Of Contents

    3M™ MicroTouch™ Controller RX142 Reference Guide Contents Introduction What You Need to Know ....................5 Important Safety Information ..................5 3M Touch Systems Support Services................6 Contact 3M Touch Systems ..................7 Chapter 1 Integrating the RX142 Controller Overview of the RX142 Controller ................9 Handling and ESD Protection ...................10...
  • Page 4 3M™ MicroTouch™ Controller RX142 Reference Guide Restore Defaults ......................24 Set Controller Number ..........Error! Bookmark not defined. Unit Type........................24 Appendix A RX142 Controller Specifications Technical Specifications....................28 Storage and Operating Temperature with Humidity Conditions.......29 3M Touch Systems, Inc. Proprietary Information...
  • Page 5: Introduction

    3M Touch Systems is committed to being a premier supplier in touch systems throughout the world. As a 3M Touch Systems customer, you are aware that we have strong internal programs that meet or exceed environmental regulations of our customers and the regions in which we conduct business.
  • Page 6: 3M Touch Systems Support Services

    Data Sheet and product label. 3M Touch Systems Support Services 3M Touch Systems provides extensive support services through our website and technical support organization. Visit the 3M Touch Systems website at http://www.3M.com\touch, where you can download touch software and drivers, obtain regularly updated technical documentation on 3M™...
  • Page 7: Contact 3M Touch Systems

    5:30 p.m. until 8:00 p.m. US Eastern Standard Time – 9 a.m. to 5 p.m. throughout Europe. You can contact 3M Touch Systems Technical Support (US only -- Eastern Standard Time) by calling the hot line, sending email or a fax.
  • Page 9: Chapter 1 Integrating The Rx142 Controller

    To integrate and test the RX142 controller, you need the following items: • A 4-wire resistive sensor. • A method of establishing the serial data communication between the controller and your system. The standard 3M™ MicroTouch™ RS-232 plug and play serial cable (P/N 7319630) is recommended. • A power source. •...
  • Page 10: Handling And Esd Protection

    The RX142 controller requires an RS-232 serial plug and play communication cable attached to connector JP2. You can use a standard 3M™ MicroTouch™ RS-232 plug and play cable (P/N 7319630) or an equivalent interconnect. One end of this cable plugs into the RS-232 connector (JP2) on the RX142 controller.
  • Page 11: Mounting The Controller

    3M™ MicroTouch™ Controller RX142 Reference Guide PC Side (9-Pin D) Controller Side (8-Pin Molex) RS-232 Assigned Jumpered to: Pin Description Request to Send (RTS) Request to Send (RTS) Clear to Send (CTS) Clear to Send (CTS) Not Used Do not ground...
  • Page 12: Mounting The Sensor

    3M™ MicroTouch™ Controller RX142 Reference Guide CAUTION To avoid possible damage to the controller, you must provide a path for electrostatic discharge (ESD). The controller mounting hole near the sensor connector should be used to connect to chassis safety ground and must be attached by the shortest possible route to a good earth return (chassis) in all applications.
  • Page 13: Status Light (Led) Diagnostics

    3M™ MicroTouch™ Controller RX142 Reference Guide Status Light (LED) Diagnostics 3M Touch Systems controllers are highly reliable units; however, there may be occasions when the controller does not perform exactly as you expected. The RX142 controller provides diagnostic feedback with a light emitting diode (LED) on the component side of the board that indicates the status of the sensor unit.
  • Page 14: Installing 3M™ Microtouch™ Software

    3M™ MicroTouch™ Controller RX142 Reference Guide Installing 3M™ MicroTouch™ Software 3M™ MicroTouch™ Software includes the driver that enables your sensor to work with your computer. 3M Touch Systems has touch drivers for many operating systems, including Windows Vista, XP, XP embedded, 2000, 9X, Windows Me, Windows CE, and Windows NT 4.0 (refer to the website for a complete listing).
  • Page 15: Chapter 2 Rx142 Controller Communications

    Format Tablet is supported by all current 3M™ MicroTouch™ controllers. • It is the standard for current 3M Touch Systems product development and is the format used by all touch drivers written by 3M Touch Systems. Refer to the Format Tablet command in the firmware reference section.
  • Page 16: Communicating With The Controller

    Mode Stream provides the best response time and overall feel. 3M Touch Systems recommends that the touch driver generate an interrupt as each packet in the data stream arrives. Because touchdown and liftoff events are specially coded, provided that the interrupts are sent as recommended, your software always knows exactly what the user is doing.
  • Page 17: Receiving Responses From The Controller

    <Header>Command Response<Terminator> Note: The following descriptions of header, response, and terminator, use 3M Touch Systems terminal emulator key sequences. The format of controller responses varies depending on the terminal emulation mode you are using.
  • Page 18: Firmware Commands

    <SOH>Response<CR> Controller Initialization To initialize the RX142 controller for new development, 3M Touch Systems recommends that the host system issue a Reset command whenever the host system is powered on and is attempting to establish communication with the controller.
  • Page 19: Calibrate 3 Point

    3M™ MicroTouch™ Controller RX142 Reference Guide Table 3 Firmware Commands for RX142 Development Command Code Description Calibrate 3 Point Initiates a 3-point calibration routine. Enter Sleep Controller enters low power mode. Format Tablet Outputs the X/Y touch coordinate data in a five-byte packet.
  • Page 20: Guidelines For The C3 Commands

    3M™ MicroTouch™ Controller RX142 Reference Guide In addition to scaling the Format Tablet output to the display, this command corrects for sensor orientation and sensor pinout variations. This information will be maintained by the controller. The Calibrate 3 Point command initiates an interactive calibration procedure which defines the active area of the sensor by mapping locations to an absolute X,Y coordinate system.
  • Page 21: Enter Sleep

    3M™ MicroTouch™ Controller RX142 Reference Guide Figure 2 Calibration Target Locations (0, 0) [0, 1024]* 1023, 0) [1024, 1024]* Upper Left Calibration Target Upper Right Calibration Target X = 1024 x 1/8 = 128 (895, 96) X = 1023 – (1024 x 1/8) = 1023 – 128 = 895...
  • Page 22: Get Controller Number

    3M™ MicroTouch™ Controller RX142 Reference Guide The low order bits (X3 – X0 and Y3 – Y0) are not significant in a 1024 by 1024 sensor because data can fluctuate with each touch, and therefore may not be completely accurate.
  • Page 23: Null Command

    Response: <SOH>CcXxxx<CR> where: = Two ASCII characters that describe the type of 3M Touch Systems controller. Xxxx = This is a unique identifier not necessarily the actual firmware revision number. Description: Returns a 6-character identifier, which describes the controller type and the firmware RX142 version number.
  • Page 24: Restore Defaults

    Description: Returns to the factory default operating parameters. The Restore Defaults command copies the 3M Touch Systems factory default parameters from ROM to the non-volatile memory (NOVRAM) and then executes a Reset command. The following table lists the factory defaults for the RX142 controller. The Restore Defaults command is useful in situations where inadvertent commands to the controller have rendered the sensor inoperative.
  • Page 25 3M™ MicroTouch™ Controller RX142 Reference Guide = Two ASCII characters that identify the controller type. Indicates the RX142 series of controllers = Four ASCII characters that indicate the features supported by the Ffff controller. Indicates a resistive controller Indicates either 4 wire controller (RX142) or an 8 wire...
  • Page 27: Rx142 Controller Specifications

    3M™ MicroTouch™ Controller RX142 Reference Guide APPENDIX A RX142 Controller Specifications This section provides controller specifications such as power requirements, environmental requirements, and cable connectors. The RX142 controller is a compact RS-232 serial controller. This controller was designed to be mounted inside your monitor.
  • Page 28: Technical Specifications

    3M™ MicroTouch™ Controller RX142 Reference Guide Technical Specifications Physical Dimensions 2.74 in. x 1.49 in. x 0.45 in. (69.6 mm x 37.8 mm x 11.4 mm) Board Level Functions 5 VDC (16 mA typical, 27 mA with touch); ± 5% regulation Power 12 VDC (19 mA typical, 30 mA with touch);...
  • Page 29: Storage And Operating Temperature With Humidity Conditions

    3M™ MicroTouch™ Controller RX142 Reference Guide Performance & Reliability Minimum Touch Duration 14 ± 1 msec Touch Resolution – 1024 x 1024 (Maximum number of addressable coordinates generated by the controller) ESD Susceptibility ±8 kV Contact Discharge – Class 2 per section 9 of IEC 61000-4-2...