STEP 2
INSTALL RANGETOP
,Slide the rangetop
into the opening. Make sure
the rangetop is evenly seated and supported.
,A hold-down
strap with screws is provided to
secure the rangetop
to the rear or side cabinet
walls.
. Remove the hold-down
strap from the back
of the rangetop. Attach one end of the strap
to the back of the rangetop.
,Secure the other end of the strap as high as
possible to the cabinet back wall or adjacent
cabinet.
Keep the strap as short as possible for
better security.
Back Wall
Hold-Down
Strap
Location and
Attachment
STEP 3
CONNECT RANGETOP TO GAS
-AWARNING
Do not use a flame to check for gas leaks.
A manual
shut-off valve must be installed where
it will be accessible.
Assure that gas is turned
off at the shut-off
valve.
.Install the supplied pressure regulator
onto the end
of the gas inlet.
,You can install a 90 ° elbow (not provided) onto the
gas inlet and route the gas connections
to avoid
interference
with drawers or other cabinetry
features. However, it is not recommended
because
it will result in a drop in gas pressure.
, Make sure the regulator
is installed in the right
direction.
See arrow on the underside
of the
regulator.
NOTE: Instead of using solid piping to connect
to pressure regulator, an approved
flexible metal
appliance
connector
may be used between the pipe
stub and the shut-off valve to the pressure regulator,
if local codes permit.
,Turn on gas and check for leaks:
-Use a liquid leak detector
at all joints and
connections
in the system.
RangetopBurner Box
1/2" N.RT.
GasInlet
) Regulator
(Supplied)
Solid Piping
or Flexible
Connector
_
hut-Off
Valve
PipeStub From
HouseGasSupply
IMPORTANT: Disconnect
the rangetop
and the
individual
shut-off valve from the gas supply piping
system during any pressure testing of that system
at test pressures greater than 1/2 psig. Isolate
the rongetop
from the gas supply piping system
by closing the individual
manual
shut-off valve
to the rongetop
during any pressure testing
of the gas supply piping system at test pressures
equal to or less than 1/2 psig.