Sanyo VR-L4110WSEC - Commercial Solutions Lab Manual page 12

Booklet
Table of Contents

Advertisement

MCO-19AIC
MCO-19AIC(UV)
MCO-19AIC(UVH)
Sterisonic
GxP Series Cell Culture CO
The industry's most complete cell culture solution for highly
regulated applications or conventional incubation.
The SANYO Sterisonic
GxP incubator
is designed for a wide array of demand-
ing and highly regulated applications in
the biomedical, pharmaceutical, medical
research and clinical laboratory.
Representing years of research, devel-
opment and component testing, the
Sterisonic
GxP incorporates a collec-
tive of mutually functional systems and
design attributes to offer a holistic solu-
tion to cell culture protocols, from the
most sophisticated to more familiar and
conventional processes. These include
but are not limited to:
Stem cell research
Autologous tissue regeneration
& regenerative medicine
• In vitro fertilization
Genomic and proteomic expression
Esoteric plant and amphibian cell culture
Genomic and proteomic expression
Hypersensitive and transgenic
cell culture
Low media volume
microplate work
Sterisonic
GxP H
0
2
2
Sterilization Cycle
(3 Hours, total)
Elapsed Time:
Conventional High Heat
Decontamination
(24 Hours, total)
12
Guide to Laboratory Equipment www.sanyobiomedical.com
2
Sterisonic
GxP Design
Elevated humidity, low water level
warning. To avoid cell culture desicca-
tion, the SANYO Sterisonic
CO
incubator maintains ~95%
2
RH at 37°C.
Ergonomic cabinet design
reversible inner and outer doors, a
single SANYO incubator offers the
industry's most flexible installation
options.
Field reversible door.
reversible door allows universal
installation using the left-hand hinge
(standard) or a right-hand hinge
modification.
Inner door and gasket.
inner design is critical to successful
contamination control technique.
PREP: 15 min.
Reposition shelves, humidity
pan and plenum inside
Start Cycle: 30 min.
SANYO chamber. Interior
Press H
surfaces are exposed.
Chamber warms to 45˚C.
15 min.
30 min.
Start Cycle: 90 min.
PREP: 15 min.
Interior chamber elevates to high heat.
Remove interior components
sensitive to high heat.
Incubators
GxP
. With
SANYO Sterisonic
The field-
with integrated H
The
O
start button.
2
2
45 min.
GxP Model MCO-19AIC(UVH)
O
sterilization system.
2
2
Sterilize: 7 min.
SANYO H
O
atomizer creates vapor which is
2
2
circulated throughout chamber by interior blower.
Resolve: 90 min.
UV lamp glows for 90 minutes,
reducing H
O
to harmless water droplets.
2
2
Finish.
Shelves, humidity pan and plenum
are returned to operating position.
3
1
2
4
Sterilize: 14 hours
Interior chamber remains at high heat.
5
6

Hide quick links: