Setup menu of
the camcorder
Main data block
MASTER BLACK
MASTER GAMMA
KNEE POINT
DETAIL LEVEL
R/B GAIN
R/B BLACK
Non-volatile memory
Hardware of the
camera section
RM-B150 connected
RM-B150 not connected
When a remote control unit is connected to the
camcorder, the "remote control data block" is
selected as the current paint data block, and the
paint adjustment parameters that were in effect
the last time the remote control unit was used are
recalled.
The settings of the absolute value rotational
1)
controls
and absolute value switches
overwritten by those on the remote control unit
after the remote control unit is connected.
When the remote control unit is disconnected
from the camcorder, the "main data block"
becomes effective. Thus the camcorder will
return to the settings that were in effect before the
remote control unit was connected.
1) Absolute value rotational controls: The data
corresponding to the angular position of controls is
output. Rotational controls for which the data
corresponding to the amount of their rotation is output
are called relative value controls.
2) Absolute value switches: Like toggle switches or
slide switches (except most momentary switches), the
switches (or knobs) whose positions must coincide
with their functions are called absolute value switches.
When MAINTENANCE >Camera Config >RM
Common Memory is set to [On] in the setup
menu, you can use settings of the paint
adjustment data stored in the main data block
even if you connect the remote control unit. In
this case, the settings stored in the main data
block will be renewed when you change the
RM-B150
Remote control
data block
MASTER BLACK
MASTER GAMMA
KNEE POINT
DETAIL LEVEL
R/B GAIN
R/B BLACK
2)
are
settings on the remote control unit. Thus, the
settings of the paint data made with the remote
control unit can be retained even if the remote
control unit is removed. However, if the switch
position on the remote control unit differs from
the one on the camcorder, the switch position on
the camcorder takes precedence over that on the
remote control unit.
Also, it is possible to keep the settings that are in
effect before you connect the remote control unit.
In this case, you should set the control knob to the
relative value mode on the remote control unit.
For details, refer to the Operation Manual supplied
with the remote control unit.
Operating the Menu from the
RM-B150
1
Set the DISPLAY switch to MENU.
The camcorder menus can be displayed on a
video monitor connected to the MONITOR
connector of the RM-B150.
2
Select and set the menu items, using the
MENU SELECT knob and the
CANCEL/ENTER switch.
3
When the settings are completed, set the
DISPLAY switch to ON or OFF to exit
the menu.
For details on operations of the RM-B150, refer to
the Operation Manual of the RM-B150.
Operating the Menu from the
RM-B750
1
Press and light the MONITOR button
then press the VF MENU button.
The camcorder menus can be displayed on
the RM-B750's display or a video monitor
connected to the MONITOR connector of the
RM-B750.
2
Select and set the menu items, using the
MENU SELECT knob, ENTER button,
and CANCEL button.
3
When the settings are completed, press
the VF MENU button to exit the menu.
Operating from the RM-B150/B750