Communication Parameters

Baud rate : 9600 bps ( UART )
A
Data length : 8 bits
A
Parity : None
A
Command Reference List
01. Power
02. Input Select
03. Aspect Ratio
04. Screen Mute
05. Volume Mute
06. Volume Control
07 . Contrast
08. Brightness
09. Colour
10. Tint
1 1. Sharpness
1 2. OSD Select
1 3. Remote control lock mode k
1 4. Balance
1 5. Colour Temperature
1 6. Red Adjustment
1 7 . Green Adjustment
1 8. Blue Adjustment
19. Abnormal Status
20. ISM Method
21. Low Power
22. Auto Configure
23. Channel Select Command m
24. Send IR Code
25. Input select (Main)
* When setting the 19 ~ 25, a menu doesn't display on screen.
104
Stop bit : 1 bit
A
Communication code : ASCII code
A
Use a crossed (reverse) cable.
A
COMMAND
COMMAND
DATA
1
2
(Hexadecimal)
k
a
0 ~ 1
k
b
Refer to p. 105
k
c
Refer to p. 105
k
d
0 ~ 1
k
e
0 ~ 1
k
f
0 ~ 64
k
g
0 ~ 64
k
h
0 ~ 64
k
i
0 ~ 64
k
j
0 ~ 64
k
k
0 ~ 64
k
l
0 ~ 1
m
0 ~ 1
k
t
0 ~ 64
k
u
0 ~ 3
k
v
0 ~ 50
k
w
0 ~ 50
k
$
0 ~ 50
k
z
0 ~ 9
j
p
Refer to p. 107
j
q
0 ~ 1
j
u
a
Refer to p. 108
m
c
Key Code
x
b
Refer to p. 108
Transmission / Receiving Protocol
Transmission
[Command1][Command2][ ][Set ID][ ][Data][Cr]
* [Command 1] : First command to control the set.
* [Command 2] : Second command to control the set.
* [Set ID]
* [DATA]
* [Cr]
* [ ]
OK Acknowledgement
[Command2][ ][Set ID][ ][OK][Data][x]
* The set transmits ACK (acknowledgement) based on
this format when receiving normal data. At this time, if
1
the data is data read mode, it indicates present status
data. If the data is data write mode, it returns the
data of the PC computer.
Error Acknowledgement
[Command2][ ][Set ID][ ][NG][Data][x]
* The set transmits ACK (acknowledgement) based on
this format when receiving abnormal data from
non-viable functions or communication errors.
Data 1: Illegal Code
2: not support function
3: Wait more time
(j, k, m or x)
: You can adjust the set ID to choose
desired monitor ID number in option
menu.
Adjustment range is 1 ~ 99.
When selecting Set ID '0' , every
connected the set is controlled.
Set ID is indicated as decimal (1~99) on
menu and as Hexa decimal (0x0~0x63)
on transmission/receiving protocol.
: To transmit command data.
Transmit 'FF' data to read status of
command.
: Carriage Return
ASCII code '0x0D'
: ASCII code 'space (0x20)'