Frigidaire FGHB2866PF Service Data Sheet

Service data sheet
Hide thumbs Also See for FGHB2866PF:

Advertisement

PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0°
CONTROL SETTING
Type A with Run / Start
65°F (18°C) Ambient
90°F (32°C) Ambient
Capacitor
90 to 100%
Operating Time
Freezer Temperature
-5° to 2°F (-20° to -17°C)
-1° to 3°F (-18° to -16°C)
Refrigerator Temperature
34° to 39°F (1° to 4°C)
34° to 39°F (1° to 4°C)
Low Side Pressure
-2 to 6 psig ( -14 to 41 kPa)
-2 to 6 psig (-14 to 41 kPa)
High Side Pressure (last 1/3
85 to 105 psig (586 to 724 kPa)
120 to 135 psig (827 to 931
cycle)
Wattage (last 1/3 cycle)
30 to 50
Amps (running)
.4 to .8
Base Voltage
115 vac (127 vac max)
DEFROST SPECIFICATIONS
Thermostat
Cabinet Size
Cut-in
Cut-out
Watts
25°F (-4°C)
47°F
500
26' & 28' SD, 23' CD
(8°C)
Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run
time.
CONDENSER FAN MOTOR
Watts
RPM
3.1
1100 CW Opposite Shaft
0.03 Running
FREEZER ICE MAKER SPECIFICATIONS
Electrical
115 vac (127 vac max)
Thermostat
Opens at 48°F ( 9°C), Closes at 15° F ( -9°C)
Heater Voltage
115 vac
FREEZER ICE MAKER CONNECTOR PLUG CONNECTIONS
Wire Number
Wire Color
Connects to:
1
Green / Yellow
2
Yellow
3
Black
4
Light Blue
CAUTION
All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch
to touch insulation; it will char at 200°F and flash ignite (burn) at 500°F. Excessive
heat will distort the plastic liner.
100%
IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION.
Error Codes
kPa)
Display
50 to 70
Interpretation
FZ
FF
.7 to .9
--
OP
Open FF Thermistor
OP
--
Open FZ Thermistor
--
SH
Shorted FF Thermistor
Shorted FZ Thermistor
Heater
SH
--
Ohms
UI to Main Control
SY
CF
Board communication
26.5
failure; on start up
UI Main Control Board
SY
CE
communication error;
after a period in operation
SY
EF
Evaporator Fan Failure
Amps
Activate:
Press ٨ and V temperature pads for up to 10 sec. simultaneously.
Press + or - to move forward or backward through tests.
Deactivate:
Press + for up to 10 sec. FFIM Diagnostic Mode will automatically deactivate after 5 min. of inactivity.
NOTE: Silence alarm.
Test
52C
Ice Maker Thermistor
55C
Water Valve
57C
Evaporator Fan (FFIM)
Ground
Ice Level Sensor
Water Valve
58C
Line
63C
Twist Tray
Neutral
Variable Capacity Compressor (VCC) Diagnostics (select models)
If test 38 fails, diagnose as follows:
Check at the connector from the power cord
harness into the inverter board, located in
the machine compartment.
yes
(PUR and WHT wires)
Is Inverter Board receiving 115 VAC
from power supply?
no
Check voltage supply.
Check and repair power
cord harness wiring and
connections.
FREEZER ICE MAKER INFORMATION
(Where Applicable)
Test Cycling: Remove cover by inserting screwdriver in notch at bottom and prying cover
from housing. Use screwdriver to rotate motor gear counterclockwise until holding switch
circuit is completed. All components of ice maker should function to complete the cycle.
Water Fill Volume: The water fill adjustment screw will change the fill time. One full
turn is equal to 20cc (.68 oz.). The correct fill is 102 to 130cc (3.4 to 4.3 oz.). When
a water valve is replaced, the fill volume must be checked.
SERVICE DATA SHEET
242292100
ICE & WATER - AUTOMATIC DEFROST
BOTTOM FREEZER - R134a
Special Modes
Display
Activate/Deactivate
Mode
(press for up to 10 sec. simultaneously)
FZ
FF
Manual Defrost
d
F
+ and - / same to deactivate
Display / Showroom
77
77
٨ and - / Power-on-Reset (POR)
Sabbath
Sb
Sb
٧ and + / same to deactivate
٨ and ٧/ + to deactivate
System Diagnostic
No FF or FZ display,
all UI LEDs on.
٨ and + together to activate /
FFIM Diagnostic
Numerical display of
first test
press and hold + to deactivate
Notes:
• Always check for pin back-outs, pinched or damaged wires before replacing components.
• Determine whether failure is caused by the component, main control board or wiring. Contact
TID before replacing main control board.
• Refer to Service Manual for additional information.
Fresh Food Ice Maker Diagnostic Mode
To activate test
Passing Result
Activates
FZ display shows temperature sensed by Ice Maker Thermistor.
automatically
"OP" if open; "SH" if short
Set
Remove ice tray to collect water into a measuring container to measure wa-
ter fill. If collecting water into ice tray, first perform test 63C to empty ice tray.
Set
"On" on FZ display when fan activated, "OFF" when deactivated.
Activates
Remove ice bucket.
automatically
Allow bail arm to drop freely. Pass if no alarm when tray returns to "home" position.
Hold bail arm up. Pass if alarm sounds when tray returns to "home" position.
This test runs continuously until another test is selected.
Set
Remove ice bucket.
FZ display shows "1" and "GOOD".
Check at Inverter Board on
Remove inverter box from the
Check connections from Inverter
Compressor
compressor and check resistance
Board to Compressor
(BLK and RED wires)
across compressor winding pairs as
yes
yes
Are connections from Inverter
shown.
Board to Compressor intact?
Is Inverter Board receiving 10-15
Is resistance across all winding
VAC and 1-5 VDC from Main
pairs equal?
Control Board?
no
no
Replace Compressor and
Identify and repair damaged
Inverter Board.
wires or poor connections
between Inverter Board and
Compressor.
Check at Main Control Board
(BLK/WHT and RED/BLK wires)
no
Replace Main Control Board.
Is Main Control Board sending
10-15 VAC and 1-5 VDC to
Inverter Board?
VCC Resistance Check
yes
Check resistance between terminals 1 and
2, 2 and 3, 3 and 1.
Identify and repair damaged wires or
If all resistances are equal,
poor connections between Main Control
compressor is operative.
Board and Inverter Board.
Water Fill
Adjustment
Motor
Gear
Mounting
Plate
Screws
Mounting
Plate
Screw
Timing
Gear
Activate:
Press ٨ and ٧ for up to 10 sec. simultaneously.
Deactivate:
Press + for up to 10 sec. Diagnostic Mode will automatically deactivate after 5 min. of inactivity.
Note: Silence alarm.
• Tests marked with "*" may not be applicable to this unit and will not be displayed in System Diagnostic Mode.
• Tests displayed in diagnostic mode but not described below are for internal purposes only; advance through.
• View UI display for "on," "off," "CL," "OP," "SH," "LO," "HI" or numerical results of tests.
• Listen for operating sounds; feel for heat or air flow as appropriate to determine results of tests.
Test
To activate test:
--
First Screen
--
--
Second Screen
--
--
Third Screen
--
28
Dispenser Paddle
Press disp. paddle
1*
Standard
Set
Compressor
2
Defrost Heater
Set
3
FF Light
Set
8
Water Valve
Set
(Dispenser)
9
FZ Light
Set
10
Auger Motor
Set
11
Cube/Crush
Set
Solenoid
41*
Perfect Temp Drawer
Set
(PTD)
12*
VCC Condenser Fan
Set
38*
VCC Compressor
Set
15
Evaporator Fan
Set
36
Ice Chute Door
Depress ice chute door
or set
22
Damper
Set
23
FF Door
Open/close FF door
24
FZ Door
Open/close FZ door
26
Defrost Limit Switch
Activates automatically
29
FF Thermistor Mid-
Activates automatically
level
30
FZ Thermistor
Activates automatically
33
Ambient Thermistor
Activates automatically
@ Main Board
35*
FF Thermistor
Activates automatically
Upper-Level
34*
Ambient Thermistor
Activates automatically
@ UI
0-
Firmware
Set
no
Parameters
2-
Main Board
Set
Firmware
4-
UI Firmware
Set
yes
Replace Inverter Board
IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualified repair personnel only. Untrained persons
should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before
servicing this appliance.
IMPORTANT
If any green grounding wires are removed during servicing, they must be returned to their original position
and properly secured.
System Diagnostic Mode
Passing result
All LED lights on UI illuminated
All segments on UI temperature displays illuminated
Blank UI display, no lights illuminated, no shadowing; "-" and "+"
blinking on FF display side to show location.
"on" on UI when depressed; "off" when released
Compressor running when "on"; stopped when "off"
Defrost limit switch must be closed; verify "CL" in test 26.
Feel for heat from defrost heater when "on".
If "OP" in test 26, heater will not activate.
With FF door open, FF lights on when "on"; off when "off"
Be prepared to collect water at dispenser.
Water dispenses when "on"; stops when "off"
With FZ door open, FZ lights on when "on", off when "off"
FF door must be closed.
Motor running when "on"; motor stopped when "off"
FF door must be closed. Do not leave solenoid in activated state.
Solenoid activated when "on"; deactivated when "off"
PTD UI illuminated when "on", off when "off"
Fan running when "on"; stopped when "off"
Compressor running when "on"; stopped when "off"
Fan running for minimum of 10 sec. when "LO" or "HI"; stopped when
"off". Feedback failure if fan starts but runs less than 10 sec. Listen for
speed change from "LO" to "HI".
"OP" on UI when manually opened; "CL" when closed. Or, using "power on-
off", "OP" on UI when solenoid activated, "CL" when deactivated
With inspection mirror, observe damper open when "OP"; closed when "CL"
"CL" on UI when door closed; "OP" when open
"CL" on UI when door closed; "OP" when open
"CL" on UI when closed; "OP" when open
UI shows temperature sensed by FF thermistor; pass if within 10°F of
temperature measured with gauge at mid-level FF thermistor location.
"OP-" if open; "SH-" if short
UI shows temperature sensed by FZ thermistor; pass if within 10°F of temperature
measured with gage at FZ thermistor location.
"OP" if open; "SH" if short
UI shows temperature sensed at main board; pass if within +20°F/-10°F of
temperature measured with gauge at main board location.
"OP" if open; "SH" if short
UI shows temperature sensed by upper level FF thermistor; pass if within
10°F of temperature measured with gauge at upper-level FF thermistor loca-
tion. "OP¯" if open; "SH¯" if short
UI shows temperature sensed at UI; pass if within +20°F/-10°F of tempera-
ture measured with gauge at UI location. "OP" if open; "SH" if short
Displays digit sequence; record
Displays digit sequence; record
Displays digit sequence; record