Advertisement

Error Code
Message Information
CPU0701
Message
Details
Action
CPU0702
Message
Details
Action
CPU0703
Message
Details
Action
CPU0704
Message
Details
Action
88
number > protocol error detected.
CPU <
System event log and operating system logs may indicate that the
exception is external to the processor.
1. Check system and operating system logs for exceptions. If no
exceptions are found, continue.
2. Turn off the system and remove input power for one minute.
3. Ensure the processor is seated correctly.
4. Reapply input power and turn on the system.
5. If the issue persists, see
CPU bus parity error detected.
System event log and operating system logs may indicate that the
exception is external to the processor.
1. Check system and operating system logs for exceptions. If no
exceptions are found, continue.
2. Turn off the system and remove input power for one minute.
3. Ensure the processor is seated correctly.
4. Reapply input power and turn on the system.
5. If the issue persists, see
CPU bus initialization error detected.
System event log and operating system logs may indicate that the
exception is external to the processor.
1. Check system and operating system logs for exceptions. If no
exceptions are found, continue.
2. Turn off the system and remove input power for one minute.
3. Ensure the processor is seated correctly.
4. Reapply input power and turn on the system.
5. If the issue persists, see
number > machine check error detected.
CPU <
System event log and operating system logs may indicate that the
exception is external to the processor.
1. Check system and operating system logs for exceptions. If no
exceptions are found, continue.
Getting
Help.
Getting
Help.
Getting
Help.