Figure 3.4 Surface Cover Temperature Measurement Points; Table 3.1 Surface Temperature Measurement Points And Standard Values - Fujitsu MHW2040BS Product Manual

Fujitsu computer drive user manual
Table of Contents

Advertisement

Installation Conditions
(4) Ambient temperature
The temperature conditions for a disk drive mounted in a cabinet refer to the
ambient temperature at a point 3 cm from the disk drive. The ambient
temperature must satisfy the temperature conditions described in Section 1.4, and
the airflow must be considered to prevent the DE surface cover temperature from
exceeding 60 °C.
Provide air circulation in the cabinet such that the PCA side, in particular,
receives sufficient cooling. To check the cooling efficiency, measure the surface
cover temperatures of the DE. Regardless of the ambient temperature, this
surface cover temperature must meet the standards listed in Table 3.1. Figure 3.4
shows the temperature measurement point.

Figure 3.4 Surface cover temperature measurement points

Table 3.1 Surface temperature measurement points and standard values

No.
1
For details of the reliability for each temperature range, refer to the
Section 1.7, "Reliability."
3-6
1
Measurement point
DE cover
IMPORTANT
Temperature
60°C max
C141-E249